izpis_h1_title_alt

Nosilnost dvostrižne vijačne zveze smrekovih nosilcev
ID Ferlež, Klemen (Author), ID Fajdiga, Gorazd (Mentor) More about this mentor... This link opens in a new window, ID Gospodarič, Bojan (Comentor)

.pdfPDF - Presentation file, Download (2,01 MB)
MD5: 649FCA9F11E2C44B85DFB035181EC65C

Abstract
V diplomski nalogi smo se osredotočili na dimenzioniranje dvostrižne vijačne zveze smrekovih nosilcev in pri tem upoštevali standard Evrokod 5 za projektiranje lesenih konstrukcij. Namen naloge je bil ugotoviti nosilnost izbrane vijačne zveze in slednjo potrditi z eksperimentom. V teoretičnem delu naloge smo izračunal karakteristično in projektno bočno nosilnost vijakov ter določil potrebno število vijakov za prenos izbrane obremenitve 25 kN. Pri dimenzioniranju smo upošteval specifične parametre lesa in vijakov. Eksperimentalni del je vključeval pripravo vzorcev iz smrekovega lesa C22, ter izvedbo obremenitvenega preskusa na stroju Zwick Roell. Rezultati izvedenega preskusa so potrdili izračunano nosilnost dvostrižne vijačne zveze smrekovih nosilcev.

Language:Slovenian
Keywords:dimenzioniranje, eurokod 5, dvostrižna vijačna zveza, lesene konstrukcije
Work type:Bachelor thesis/paper
Organization:BF - Biotechnical Faculty
Year:2024
PID:20.500.12556/RUL-162141 This link opens in a new window
Publication date in RUL:19.09.2024
Views:48
Downloads:1028
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Load capacity of a double-shear screw connection of spruce beams
Abstract:
In this thesis, we focused on the dimensioning of a double-shear screw connection of spruce beams, following the Eurocode 5 standard for the design of timber structures. The purpose of the thesis was to determine the load capacity of the selected screw connection and to verify it through experimentation. In the theoretical part, we calculated the characteristic and design lateral load capacities of the screws and determined the required number of screws to transfer the selected load of 25 kN. In the dimensioning process we considered specific parameters of the wood and screws, such as density, lateral strength, and correction factors. The experimental part involves the preparation of a sample made of spruce timber C22 and executing a load test using a Zwick Roell machine. The results showed that the calculated load capacity corresponds to the experimentally obtained data, confirming the adequacy of the selected screw connection for use in structures.

Keywords:dimensioning, eurocode 5, double-shear screw connection, timber structures

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back