Abstract
Diplomsko delo se osredotoča na preskušanje nosljivih merilnih naprav v obliki prstana. Glavni problem, ki ga delo obravnava, je ocena učinkovitosti in zanesljivosti teh naprav pri merjenju elektrodermalne aktivnosti (EDA), elektrokardiograma (EKG), fotopletizmograma (PPG) in temperaturnih podatkov v različnih pogojih. Metode, uporabljene v raziskavi, vključujejo hkratno uporabo več prstanov, oceno vpliva položaja namestitve in nehotenih premikov prsta, zapestja ali roke ter merjenje časa polnjenja in trajanja baterije. Rezultati eksperimentalnega dela so pokazali, da so nosljive merilne naprave zanesljive in natančne, kar pomembno prispeva k boljšemu razumevanju in sprejemanju tovrstnih tehnologij v praktični uporabi. Glavni zaključek raziskave je, da merilne naprave v obliki prstana ponujajo obetavno rešitev za natančno spremljanje bioloških signalov v realnem času.

Language:Slovenian
Keywords:nosljive naprave, merilni prstani, elektrodermalna aktivnost (EDA), elektrokardiogram (EKG), fotopletizmogram (PPG), zanesljivost
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Electrical Engineering
Year:2024
PID:20.500.12556/RUL-160920-f5006ab0-d5e4-9bec-1957-638812e1eec4 This link opens in a new window
COBISS.SI-ID:206525699 This link opens in a new window
Publication date in RUL:05.09.2024
Views:215
Downloads:51
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Testing of wearable ring-shaped measuring devices
Abstract:
The thesis focuses on the testing of wearable measurement devices in the form of rings. The primary problem addressed in this work is the assessment of the effectiveness and reliability of these devices in measuring electrodermal activity (EDA), electrocardiogram (EKG), photoplethysmogram (PPG), and temperature data under various conditions. The methods used in the research include the simultaneous use of multiple rings, evaluation of the impact of placement position and involuntary movements of the finger, wrist, or hand, as well as measuring the charging time and battery life. The results of the experimental part demonstrated that the wearable measurement devices are reliable and accurate, significantly contributing to a better understanding and acceptance of such technologies in practical applications. The main conclusion of the research is that ring-shaped measurement devices offer a promising solution for accurately monitoring biological signals in real-time.

Keywords:wearable devices, measurement rings, electrodermal activity (EDA), electrocardiogram (ECG), photoplethysmogram (PPG), reliability