Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Test of three-storey confined masonry structure built from clay blocks and PU glue
ID
Gams, Matija
(
Avtor
),
ID
Triller, Petra
(
Avtor
),
ID
Tomaževič, Miha
(
Avtor
),
ID
Jäger, Andreas
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(16,04 MB)
MD5: 874667E0C4D2F4CA057A1B72531A9867
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S2352710224012646
Galerija slik
Izvleček
The paper presents an experimental test of a nearly full-scale three-storey model of a confined masonry structure. The walls were constructed using newly developed clay masonry blocks, with large holes filled with thermal insulation and polyurethane glue instead of mortar. In the construction, relatively thick 38 cm walls and large tie-columns with 25 cm × 25 cm plan dimensions. The test model was built as confined masonry according to Eurocode 8. The innovative materials and construction were developed for thermal efficiency and the test was intended to verify the structural response. The model, test setup, and test procedures are described, and the results of the tests are analysed. The building responded primarily in shear, and ultimately failed in the ground floor in a storey mechanism, but there was also substantial damage on the floor above. Due to the non-standard dimensions of the tie-columns and because masonry was thicker than the tie-columns, the in-plane loaded walls developed an interesting response mechanism in which protruding masonry sheared off. Although this did not significantly impact the overall response, it led to the earlier onset of the significant damage limit state of the structure. The model responded well with wide hysteretic loops and distributed damage, which indicated large energy dissipation capacity, and the response envelopes showed gradual strength deterioration after peak load. The response of the model was quantitatively estimated using the N2 method. Calculations showed that the tested model could withstand a design seismic load corresponding to a 0.21 g peak ground acceleration with significant damage and almost 0.52 g before collapsing. The overstrength was estimated at 1.71.
Jezik:
Angleški jezik
Ključne besede:
confined masonry
,
seismic response
,
vertically perforated blocks
,
polyurethane glue
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
FGG - Fakulteta za gradbeništvo in geodezijo
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2024
Št. strani:
18 str.
Številčenje:
Vol. 91, art. 109696
PID:
20.500.12556/RUL-158299
UDK:
69
ISSN pri članku:
2352-7102
DOI:
10.1016/j.jobe.2024.109696
COBISS.SI-ID:
197310723
Datum objave v RUL:
03.06.2024
Število ogledov:
352
Število prenosov:
44
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Journal of building engineering
Založnik:
Elsevier
ISSN:
2352-7102
COBISS.SI-ID:
525380633
Licence
Licenca:
CC BY-NC 4.0, Creative Commons Priznanje avtorstva-Nekomercialno 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by-nc/4.0/deed.sl
Opis:
Licenca Creative Commons, ki prepoveduje komercialno uporabo, vendar uporabniki ne rabijo upravljati materialnih avtorskih pravic na izpeljanih delih z enako licenco.
Projekti
Financer:
ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:
J2-6749
Naslov:
Obnašanje večetažnih strižnih sten z odprtinami pri potresni obtežbi
Financer:
ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:
P2-0185
Naslov:
Potresno inženirstvo
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj