izpis_h1_title_alt

Surgeon-stratified periprosthetic fracture risk in a single-hospital cohort of 1531 uncemented ABG-II femoral stems at primary total hip arthroplasty
ID Kropivšek, Luka (Author), ID Antolič, Vane (Author), ID Mavčič, Blaž (Author)

.pdfPDF - Presentation file, Download (705,52 KB)
MD5: 717319F343E45C65BF98DC5262EAA3B3
URLURL - Source URL, Visit https://link.springer.com/article/10.1007/s43465-023-00996-2 This link opens in a new window

Abstract
Purpose Late periprosthetic fracture risk with uncemented ABG-II femoral stems at primary total hip arthroplasty (THA) has been reported before, but single-hospital surgeon-stratified reports of this implant have never been published. We asked whether periprosthetic fracture rates of ABG-II femoral stems implanted at a single tertiary hospital depended on patients’ age, gender and the operating surgeon. Methods The study included 1531 consecutive primary ABG-II femoral stems implanted at a single tertiary hospital between January 1, 2012 and December 31, 2018. The Kaplan–Meier and Cox regression analyses were performed after 3.6–10.6 years of follow-up. Results In the cohort, we recorded 8 intraoperative, 22 early postoperative (within 90 days of implantation) and 26 late periprosthetic fractures (over 90 days postoperatively). The revision rate of ABG-II femoral stems was 5.1/100 component-years for early and 0.3/100 component-years for late periprosthetic fractures. The Kaplan–Meier cumulative probability of periprosthetic fracture was 2.1% at one, 2.3% at 2, 3.2% at 5, and 6.5% at 10 years after the implantation. Higher patient's age at operation was an independent risk factor of subsequent periprosthetic fracture (hazard ratio 1.07, 95% confidence interval 1.03–1.10; p < 0.01), regardless of the operating surgeon. Most of the fractured femora were Dorr type C (stovepipe). Conclusion The study presents the largest published ABG-II femoral stem cohort from a single hospital so far with 9291 component-years of observation. Periprosthetic fracture risk of ABG-II increased with patients’ age, had no variability between different surgeons, and was considerably higher from other uncemented femoral stems used at the same hospital.

Language:English
Keywords:total hip arthroplasty, periprosthetic fracture, cohort analysis, surgeon stratification
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:MF - Faculty of Medicine
Publication status:Published
Publication version:Version of Record
Year:2023
Number of pages:Str. 1850-1857
Numbering:Vol. 57, iss. 11
PID:20.500.12556/RUL-154725 This link opens in a new window
UDC:616.7
ISSN on article:1998-3727
DOI:10.1007/s43465-023-00996-2 This link opens in a new window
COBISS.SI-ID:186240771 This link opens in a new window
Publication date in RUL:26.02.2024
Views:418
Downloads:33
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Indian journal of orthopaedics
Shortened title:Indian j. orthop.
Publisher:Medknow Publications
ISSN:1998-3727
COBISS.SI-ID:520739097 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back