izpis_h1_title_alt

Functional properties of nonwovens as an insulating layer for protective gloves
ID Šajn Gorjanc, Dunja (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (9,33 MB)
MD5: 473952CF5E98DE87D4B314E7C967B2A7
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2073-4360/15/3/785 Povezava se odpre v novem oknu

Izvleček
The basic intention of the present work is to analyze the influence of the incorporated microporous membrane and the technology of the needling process on the functional properties of nonwovens designed as an insulating layer for protective gloves for protection against high temperatures. The investigated nonwovens are produced in carded nonwoven formation and mechanically bonded with needle bonding. The studied nonwovens contain a microporous membrane of polyester (PES) with a thickness of 20 µm (samples marked as ST and STL). In the theoretical part of the research work, the nonwovens and some technology stages are presented. The experimental part of the present work deals with the mechanical properties: breaking stress and strain, viscoelastic properties (yield strength, elastic modulus) and elastic recovery after cyclic loading and thermal conduction. In the experimental part, permeability properties (water vapor permeability, air permeability) are also analyzed. The results of the investigation show that the samples marked as ST and STL, which contain a microporous PES membrane, have a higher breaking stress than the samples marked as T and TL without the microporous PES membrane. Samples marked as ST and STL also exhibit higher values of elongation at break and limit of recoverable deformation (stress and strain at yield) and a lower modulus of elasticity than samples marked as T and TL. The samples marked as ST and STL are mechanically bonded to the lamellar plate using forked needles and therefore have a textured (ribbed) shape that affects the improved mechanical properties. The TL and STL samples, which contain a microporous PES membrane, have higher elastic recovery and lower air permeability than the T and TL samples, while water vapor permeability is lower only for the ST sample.

Jezik:Angleški jezik
Ključne besede:nonwoven fabrics, protective gloves, mechanical properties, elastic properties, air permeability
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:NTF - Naravoslovnotehniška fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:15 str.
Številčenje:Vol. 15, iss. 3, art. 785
PID:20.500.12556/RUL-154127 Povezava se odpre v novem oknu
UDK:677
ISSN pri članku:2073-4360
DOI:10.3390/polym15030785 Povezava se odpre v novem oknu
COBISS.SI-ID:140783619 Povezava se odpre v novem oknu
Datum objave v RUL:26.01.2024
Število ogledov:199
Število prenosov:19
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Polymers
Skrajšan naslov:Polymers
Založnik:Molecular Diversity Preservation International
ISSN:2073-4360
COBISS.SI-ID:517951257 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:netkane tekstilije, zaščitne rokavice, mehanske lastnosti, elastične lastnosti, zračna prepustnost

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0213
Naslov:Tekstilije in ekologija

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Naslov:Infrastructural Centre RIC UL-NTF

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj