izpis_h1_title_alt

Vpliv predhodnega poznavanja modela avtomatskega zunanjega defibrilatorja na izvedbo prve defibrilacije : magistrsko delo
ID Metelko, Žiga (Author), ID Slabe, Damjan (Mentor) More about this mentor... This link opens in a new window, ID Dolenc, Eva (Co-mentor), ID Kvas, Andreja (Reviewer)

.pdfPDF - Presentation file, Download (1018,19 KB)
MD5: 70632A0A80EE4AC244F437C6FA44106A

Abstract
Uvod: Pomemben dejavnik za preživetje po nenadnem srčnem zastoju je čim hitrejša defibrilacija. Avtomatski zunanji defibrilatorji so narejeni tako, da jih lahko uporablja vsak kdo. V krajevni skupnosti Ljubljana Center smo od 68 javno dostopnih avtomatskih zunanjih defibrilatorjev zaznali 4 različne modele. To predstavlja večjo možnost, da bi očividec med morebitnim oživljanjem uporabil defibrilator, s katerim na usposabljanju iz temeljnih postopkov oživljanja ni rokoval. Namen: Namen raziskave je ugotoviti, kako vpliva predhodno poznavanje modela avtomatskega zunanjega defibrilatorja na čas do izvedbe prve defibrilacije ter na občutja, ki jih očividci doživljajo pri uporabi nepoznanega modela avtomatskega zunanjega defibrilatorja. Meteode: Uporabljeni sta bili kvantitativna in kvalitativna metoda raziskovanja. V kvantitativnem delu smo na primeru simuliranega srčnega zastoja merili čas rokovanja pri kontrolnem avtomatskem zunanjem defibrilatorjem, s katerim je udeleženec predhodno vadil in ga poznal ter čas rokovanja pri dvema različnima nepoznanima (eksperimentalnima) modeloma avtomatskima zunanjima defibrilatorjema. Primerjali smo povprečne čase rokovanja s kontrolnim avtomatskim zunanjim defibrilatorjem z dvema eksperimentalnima. S polstukturiranimi intervjuji smo ugotavljali občutja, ki so jih doživljali udeleženci eksperimenta med uporabo nepoznanega modela avtomatskega zunanjega defibrilatorja. Rezultati: V raziskavo je bilo vključenih 123 udeležencev. Z uporabo poznanega avtomatska zunanjega defibrilatorja so uporabniki porabili v povprečju 30 (±12) s, z nepoznanim pa 37 (±14) s do prve defibrilacije, kar je bilo statistično značilno (p = 0,000) več. Poznani avtomatski zunanji defibrilator so za 4 s vklopili hitreje (p = 0,000) in za 5 s hitreje namestili elektrode (p = 0,000). Udeleženci so pri uporabi nepoznanega avtomatskega zunanjega defibrilatorja doživljali več neprijetnih občutij kot pri poznanem modelu. Kot oviro pri delu z nepoznanim učnim modelom avtomatskega zunanjega defibrilatorja so navedli različne tehnične značilnosti, kot dejavnik pomoči pa so navedli predhodno usposabljanje. Razprava in zaključek: Rokovanje z nepoznanim avtomatskim zunanjim defibrilatorjem vpliva na čas do prve defibrilacije. Obenem na čas lahko vplivajo tudi različne tehnične značilnosti defibirlatorja. Na podlagi intervjujev ugotavljamo, da predhodno poznavanje modela avtomatskega zunanjega defibiraltorja in predznanje pripomoreta k večji samozavesti in suverenosti udeležencev. Izvajalci usposabljanj iz vsebin temeljnih postopkov oživljanja bi morali zagotoviti več različnih učnih modelov avtomatski zunanjih defibrilatorjev, da bi se tako morebitni dajalci prve pomoči s kakovostnejšo praktično vajo lahko bolje pripravili za primer, če bi morali dejansko oživljati.

Language:Slovenian
Keywords:magistrska dela, zdravstvena nega, srčni zastoj, temeljni postopki oživljanja, znanje očividcev, občutja očividce
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:ZF - Faculty of Health Sciences
Place of publishing:Ljubljana
Publisher:[Ž. Metelko]
Year:2023
Number of pages:49 str., [4] str. pril.
PID:20.500.12556/RUL-153404 This link opens in a new window
UDC:616-083
COBISS.SI-ID:179416835 This link opens in a new window
Publication date in RUL:04.01.2024
Views:276
Downloads:68
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:The influence of prior knowledge of the automatic external defibrilator model on the performance of the first defibrillation : master thesis
Abstract:
Introduction: An important factor for survival of a patient with sudden cardiac arrest is defibrillation as quickly as possible. Automated external defibrillators are designed to be used by anyone. In the local community of Ljubljana Center, we detected 4 different models of this device among 68 publicly available automated external defibrillators. This means that in case of performing resuscitation, an untrained person will likely have to operate an unfamiliar automated external defibrillators model, which they have not practiced with during basic life support training. Purpose: To determine how prior knowledge of the AED model affects the time to the first defibrillation and the emotions experienced by laypersons when using an unfamiliar automated external defibrillators model. Methods: Quantitative and qualitative research methods were used. In the quantitative part, on the example of a simulated cardiac arrest, we measured the handling time with a automatic external defibrillator (control), which the participant had previously practiced and was familiar with, and the handling time with two different unknown (experimental) models of automatic external defibrillators. We compared the average handling times of a control automatic external defibrillator with two experimental ones. Using semi-structured interviews, we determined the feelings experienced by the participants of the experiment while using an unknown model of automatic external defibrillator. Results: In the study, 123 individuals participated. Users took an average of 30 (±12) seconds to operate a familiar automatic external defibrillator, while for an unfamiliar one, they took 37 (±14) seconds, to the first defibrilation which was statistically significantly (p = 0,000) longer. The familiar automatic external defibrillator was activated for 4 seconds fester (p = 0,000) and electrodes were placed for 5 seconds faster (p = 0,000) than no-familiar automatic external defibrillator. Participants experienced more discomfort when using an unfamiliar automatic external defibrillator compared to a familiar model. Various technical characteristics of the unfamiliar automatic external defibrillator were cited as obstacles in working with an unfamiliar educational automatic external defibrillator model, and prior training was mentioned as a helping factor. Discussion and conclusion: Handling an unfamiliar automatic external defibrillator model affects the time to the first defibrillation. Additionally, various technical characteristics of the automatic external defibrillator can also influence the time. Based on interviews, we find that prior knowledge of the automatic external defibrillator model and pre-existing knowledge contribute to increased self-confidence and reliability of the participants, even when using an unfamiliar automatic external defibrillator model. Training providers in basic life support content should ensure the availability of various automatic external defibrillator models for practice to better prepare potential first aid providers with higher quality practical training, should they need to perform resuscitation in a real-life scenario.

Keywords:master theses, nursing care, cardiac arrest, basic life support, bystanders' knowledge, bystanders' feelings

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back