Your browser does not allow JavaScript!
JavaScript is necessary for the proper functioning of this website. Please enable JavaScript or use a modern browser.
Open Science Slovenia
Open Science
DiKUL
slv
|
eng
Search
Browse
New in RUL
About RUL
In numbers
Help
Sign in
A loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Enterococcus spp. in water
ID
Martzy, Roland
(
Author
),
ID
Kolm, Claudia
(
Author
),
ID
Brunner, Kurt
(
Author
),
ID
Mach, Robert L.
(
Author
),
ID
Krska, Rudolf
(
Author
),
ID
Šinkovec, Hana
(
Author
),
ID
Sommer, Regina
(
Author
),
ID
Farnleitner, Andreas H.
(
Author
),
ID
Reischer, Georg H.
(
Author
)
PDF - Presentation file,
Download
(686,33 KB)
MD5: 877C429ED158ABE3D647F39901A1A9AC
URL - Source URL, Visit
https://www.sciencedirect.com/science/article/pii/S0043135417303603
Image galllery
Abstract
Faecal pollution of water and the resulting potential presence of human enteric pathogens is a predominant threat to public health. Microbiological water quality can be assessed by the detection of standard faecal indicator bacteria (SFIB) such as E. coli or certain Enterococcus species. In recent years, isothermal amplification methods have become a useful alternative to polymerase chain reaction (PCR), allowing molecular diagnostics with simple or no instrumentation. In this study, a novel screening method for the molecular detection of Enterococcus spp. by loop-mediated isothermal amplification (LAMP) is described. A set of six specific LAMP primers was designed to amplify a diagnostic fragment of the Enterococcus 23S rRNA gene, which is present in several enterococcal species targeted by quantitative PCR (qPCR), which is the standard technique recommended by the US Environmental Protection Agency. Sensitivity and specificity tests were performed using a set of 30 Enterococcus and non-target bacterial reference strains. It is shown that LAMP is equally sensitive and even more specific than the qPCR assay. A dilution series of Enterococcus faecalis DNA revealed that the LAMP method can reliably detect 130 DNA target copies per reaction within 45 min. Additionally, enterococci isolated from Austrian surface waterbodies, as well as a set of DNA extracts from environmental waters, were tested. Contingency analysis demonstrated a highly significant correlation between the results of the developed LAMP assay and the reference qPCR method. Furthermore, a simple staining procedure with a fluorescence dye demonstrated the identification of amplified products by eye. In conclusion, this method is an important component for the efficient screening and testing of water samples in low-resource settings lacking sophisticated laboratory equipment and highly trained personnel, requiring only a simple heating block.
Language:
English
Keywords:
Enterococcus spp.
,
faecal indicator bacteria
,
loop-mediated isothermal amplification
,
microbiological water quality
,
low-resource methods
,
molecular diagnostics
Work type:
Article
Typology:
1.01 - Original Scientific Article
Organization:
BF - Biotechnical Faculty
Publication status:
Published
Publication version:
Version of Record
Year:
2017
Number of pages:
Str. 62-69
Numbering:
Vol. 122
PID:
20.500.12556/RUL-153147
UDC:
61
ISSN on article:
1879-2448
DOI:
10.1016/j.watres.2017.05.023
COBISS.SI-ID:
178110723
Publication date in RUL:
19.12.2023
Views:
906
Downloads:
45
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Copy citation
Share:
Record is a part of a journal
Title:
Water Research
Publisher:
Pergamon
ISSN:
1879-2448
COBISS.SI-ID:
23055365
Similar documents
Similar works from RUL:
Similar works from other Slovenian collections:
Back