izpis_h1_title_alt

60 years of Charnley–Muller Alivium hip prosthesis : the revision percentage and tribo-corrosion sequelae after a mean of 27 years
ID Milošev, Ingrid (Avtor), ID Trebše, Rihard (Avtor), ID Cör, Andrej (Avtor), ID Levašič, Vesna (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,96 MB)
MD5: FD681CEBCAD7D7835C4EF2F29610B432
URLURL - Izvorni URL, za dostop obiščite https://link.springer.com/article/10.1007/s00402-023-04824-y Povezava se odpre v novem oknu

Izvleček
Introduction The main aim was to analyse the series of 29 collected cemented Charnley–Muller Alivium retrievals with the meantime in situ of 27 years. In addition, the revision rate of 1425 Alivium prostheses implanted at our institution between 1977 and 1992 was calculated. Materials and methods The revision percentage of the Alivium cohort was calculated up to 45 years of follow-up and compared to that of all total hip arthroplasties (THAs) implanted in the same period (No. 5535). Metal and polyethylene retrieved components were inspected in 29 cases for wear damage and roughness. Wear particles were retrieved from periprosthetic tissue using digestion protocols and their composition, morphology, and size distribution were investigated. Periprosthetic tissue was analysed histologically. Results The revision percentage of the Alivium cohort was 16% at 45 years of follow-up. It was comparable to all the THAs implanted at the same time (18%). The shape of polyethylene particles isolated from periprosthetic tissue corresponded to the wear pattern on polyethylene cups. Polyethylene particles were the main wear product, with the majority (68%) of particles smaller than 0.1 µm. Metal particles were rare with two types: CoCr and Cr based. Histological analysis showed that in 14 out of 18 specimens, the metal particles were graded + 1, reflecting that the metal loading in the periprosthetic tissue was low. Conclusions Our study represents valuable data not reported previously on the survival rate of Charnley–Muller prostheses at 45 years of follow-up and a unique insight into the collected retrievals from the materials’ point of view.

Jezik:Angleški jezik
Ključne besede:Charnley–Muller hip prosthesis, wear, wear particles, revision percentage
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:Str. 6021-6031
Številčenje:Vol. 143, iss. 10
PID:20.500.12556/RUL-151922 Povezava se odpre v novem oknu
UDK:617.3
ISSN pri članku:1434-3916
DOI:10.1007/s00402-023-04824-y Povezava se odpre v novem oknu
COBISS.SI-ID:146148611 Povezava se odpre v novem oknu
Datum objave v RUL:25.10.2023
Število ogledov:411
Število prenosov:34
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Archives of orthopaedic and trauma surgery
Skrajšan naslov:Arch. orthop. trauma surg.
Založnik:Springer Nature
ISSN:1434-3916
COBISS.SI-ID:513633817 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:kolčna proteza Charnley-Muller, obraba, obrabni delci, odstotek revizije

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj