izpis_h1_title_alt

Interakcije vode z ionskimi tekočinami
ID Goste, Domen (Author), ID Bešter-Rogač, Marija (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (2,52 MB)
MD5: 173CA9B37A1A38A984A81EAF117365D7

Abstract
V okviru magistrske naloge sem pripravil šest 1-alkil-3-metilimidazolijevih ionskih tekočin s karboksilatnimi protiioni s postopkom izmenjave aniona. V čiste ionske tekočine sem titriral vodo v dodatkih po 5 µL ter meril toplotni efekt z metodo izotermne titracijske kalorimetrije (ITC). Dobljen toplotni tok sem integriral, da sem dobil spremembo entalpije pri posameznem dodatku, eksperimentalne rezultate pa sem nato preračunal v entalpije mešanja vode z ionsko tekočino. Za vse preiskovane spojine so bile te negativne v celotnem koncentracijskem območju, globina minimuma pa se je manjšala z daljšanjem alkilne verige karboksilatnih anionov. V končnem delu naloge sem sistem 1-heksil-3-metilimidazolijev heksanoat/voda poskušal simulirati tudi z metodo PCSAFT.

Language:Slovenian
Keywords:ionske tekočine, karboksilati, ITC, entalpija mešanja, PC-SAFT
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Technology
Year:2023
PID:20.500.12556/RUL-150066 This link opens in a new window
COBISS.SI-ID:171714819 This link opens in a new window
Publication date in RUL:13.09.2023
Views:1208
Downloads:90
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Interactions of water with ionic liquids
Abstract:
As part of my master’s thesis, I first prepared six 1-alkyl-3-methylimidazolium ionic liquids with carboxylate counterions by anion exchange. Water was then titrated into each pure ionic liquid in 5 µL aliquots, while the heat flux was measured by isothermal titration calorimetry (ITC) and integrated over time to obtain the enthalpy change due to the addition of water. The enthalpies of mixing of the ionic liquids with water were calculated based on the experimental results. All ionic liquids have negative enthalpies of mixing over the entire concentration range, although the depth of their minima was shallower for the compounds containing anions with longer alkyl chains. In the last part of my thesis, I attempted to simulate the 1-hexyl-3-methylimidazolium hexanoate/water system using PC-SAFT.

Keywords:ionic liquids, carboxylates, ITC, enthalpy of mixing, PC-SAFT

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back