Ker meritve hrupa neobremenjenega elektromotorja niso dober pokazatelj hrupa obremenjenega izdelka na aplikaciji, smo zasnovali merilni sistem za meritve hrupa obremenjenega elektromotorja. Mehansko smo ga obremenili preko jermenskega gonila s servo motorjem in njegovo raven zvočne moči primerjali z ravnjo zvočne moči električno preobremenjenega elektromotorja. Zvočno moč smo ovrednotili z meritvami zvočnega tlaka z 20 mikrofoni v gluhi sobi. Ugotovili smo, da merilni sistem ni primeren za ovrednotenje zvočne moči samega elektromotorja, je pa uporaben za primerjavo hrupa različnih vzorcev obremenjenih elektromotorjev.

Language:Slovenian
Keywords:merilni sistemi, obremenjeni elektromotorji, hrup in vibracije, raven zvočne moči, gluha soba
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[Ž. Komel]
Year:2023
Number of pages:XXII, 60 str.
PID:20.500.12556/RUL-148551 This link opens in a new window
UDC:621.317:613.644(043.2)
COBISS.SI-ID:165002755 This link opens in a new window
Publication date in RUL:26.08.2023
Views:584
Downloads:39
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Measurement setup for noise characterization of a loaded electric motor
Abstract:
Noise measurements of an unloaded electric motor are not sufficient noise indicators of a loaded product on an application. For this purpose, we have designed a measurement setup for noise characterization of a loaded electric motor. It was mechanically loaded with a belt drive, connected to a servo motor. Its sound power level was compared to the sound power level of an electrically overloaded electric motor. The sound power was evaluated from sound pressure measurements with 20 microphones in an anechoic chamber. We concluded that the measurement system is not suitable for evaluating the sound power of the electric motor itself, but it is useful for comparing noise of different samples of loaded electric motors.

Keywords:measurement setups, loaded electric motors, noise and vibration, sound power level, anechoic chamber