izpis_h1_title_alt

The effect of design and size of the fluid-bed equipment on the particle size-dependent trend of particle coating thickness and drug prolonged-release profile
ID Brezovar, Teja (Avtor), ID Hudovornik, Grega (Avtor), ID Perpar, Matjaž (Avtor), ID Luštrik, Matevž (Avtor), ID Dreu, Rok (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (3,18 MB)
MD5: 4CA7EFF53A9906F6DE347090DCD700A8
URLURL - Izvorni URL, za dostop obiščite https://link.springer.com/article/10.1208/s12249-023-02540-9 Povezava se odpre v novem oknu

Izvleček
The focus of the current work is to study and demonstrate the impact of the design, the scale, and settings of fluid-bed coating equipment on the differences in pellet coating thickness, which in case of prolonged-release pellets dictates the drug release. In the first set of coating experiments, the pellet cores were coated with the Tartrazine dye with the aim of estimating the coating equipment performance in terms of coating thickness distribution, assessed through color hue. In the second set, drug-layered pellets were film-coated with prolonged-release coating and dissolution profile tests were performed to estimate the thickness and uniformity of the coating thickness among differently sized pellets. In both study parts, film coating was performed at the laboratory and the pilot scale and essentially two types of distribution plate and different height adjustments of the draft tube were compared. The dye coating study proved to be extremely useful, as the results enable process correction and the optimal use of the process equipment in combination with the appropriate process parameters. Preferential film coating of larger drug-containing pellets was confirmed on the laboratory scale, while on the pilot scale, it was possible to achieve preferential coating of smaller pellets using rational alternatives of settings, which is desirable in terms of particle size-independent drug release profile of such prolonged-release dosage forms.

Jezik:Angleški jezik
Ključne besede:pellet film coating, Wurster chamber, swirl generator, prolonged release, preferential coating
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FFA - Fakulteta za farmacijo
FS - Fakulteta za strojništvo
MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:16 str.
Številčenje:Vol. 24, iss. 4, art. 93
PID:20.500.12556/RUL-145071 Povezava se odpre v novem oknu
UDK:615.45:661.12
ISSN pri članku:1530-9932
DOI:10.1208/s12249-023-02540-9 Povezava se odpre v novem oknu
COBISS.SI-ID:147500291 Povezava se odpre v novem oknu
Datum objave v RUL:03.04.2023
Število ogledov:681
Število prenosov:114
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:AAPS PharmSciTech
Skrajšan naslov:AAPS PharmSciTech
Založnik:American Association of Pharmaceutical Scientists, Springer Nature
ISSN:1530-9932
COBISS.SI-ID:1247345 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:peletna filmska prevleka, wursterjeva komora, vrtinčni generator, podaljšano sproščanje, prednostna prevleka, farmacevtska tehnologija, farmacevtske oblike

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0189
Naslov:Farmacevtska tehnologija: od dostavnih sistemov učinkovin do terapijskih izidov zdravil pri otrocih in starostnikih

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0162
Naslov:Večfazni sistemi

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj