izpis_h1_title_alt

VREDNOTENJE KAKOVOSTI EPRUVET ZA VAKUUMSKI ODVZEM KRVI ZA KOAGULACIJSKE DOLOČITVE
ID Klobučar, Tadej (Author), ID Gros, Nataša (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (890,90 KB)
MD5: 4DA3814E4D6280D4C8DB4C1E649A1E5C

Abstract
Prenizka ali previsoka koncentracija antikoagulanta v epruvetah za vakuumski odvzem krvi lahko povzroči odstopanje rezultata in posledično vodi v napačno interpretacijo krvne slike. Zaradi tega je pomembno, da so koncentracije antikoagulanta v vakuumskih epruvetah znotraj definiranega območja, nečistote, ki vplivajo na delovanje antikoagulanta, pa v čim nižjih koncentracijah. V enem izmed tipov vakuumskih epruvet za odvzem krvi kot antikoagulant nastopa citrat, ki je bodisi zgolj natrijev citrat bodisi kombinacija natrijevega citrata in citronske kisline. Citrat veže kalcij iz krvi in s tem prepreči strjevanje krvi. Epruvete za vakuumski odvzem krvi naj bi vsebovale točno določeno koncentracijo antikoagulanta in točno določen podtlak, ki določa volumen vsesane krvi. V svoji magistrski nalogi sem vrednotil kakovost epruvet za vakuumski odvzem krvi. Z različnimi načini polnjenja epruvet sem želel pridobiti vpogled v točnost in ponovljivost količine antikoagulanta, ki je vnesena v epruveto v času proizvodnje, pridobiti vpogled v padanje vakuuma znotraj epruvet in časovno spreminjanje koncentracije antikoagulanta po dodatku vsesanega volumna krvi oz. vode. Po pričakovanjih je vakuum znotraj epruvete s časom padal, posledično pa je naraščala koncentracija antikoagulanta. Glavni vzrok odstopanja predstavlja netočen vnos količine antikoagulanta v času proizvodnje ter izhlapevanje raztopine iz epruvet.

Language:Slovenian
Keywords:natrijev citrat, UV-Vis spektrometrija, epruvete, antikoagulant
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Technology
Year:2023
PID:20.500.12556/RUL-144950 This link opens in a new window
COBISS.SI-ID:147010307 This link opens in a new window
Publication date in RUL:24.03.2023
Views:408
Downloads:105
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:QUALITY EVALUATION OF VACUUM BLOOD COLLECTION TUBES FOR COAGULATION TESTS
Abstract:
Too low or too high of a concentration of anticoagulant in the vacuum tube can cause a deviation of the result and consequently lead to a false interpretation of the blood test. For this reason, it is important that the concentration of the anticoagulant in the vacuum test tube is within the defined range, and that the impurities that affect the functioning of the anticoagulant are in the lowest possible concentrations. In one of the types of vacuum blood collection tubes, citrate acts as an anticoagulant, which is either just sodium citrate or a combination of sodium citrate and citric acid. Citrate binds calcium from the blood and thus prevents blood clotting. Tubes for vacuum blood collection should contain a specific concentration of anticoagulant and a specific under-pressure that determines the volume of blood drawn. In my master's thesis, I evaluated the quality of vacuum blood collection tubes. With different methods of filling the tubes, I wanted to gain insight into the accuracy and repeatability of the amount of anticoagulant that is introduced into the tube during production, gain insight into the drop in vacuum inside the tubes and changes in the anticoagulant concentration over time after the addition of the aspirated volume of blood or water. As expected, the vacuum inside the tube decreased with time, and as a result, the anticoagulant concentration increased. The main source of bias is the imprecise introduction of the amount of anticoagulant during production and the evaporation of the solution from the tubes.

Keywords:sodium citrate, UV-Vis spectroscopy, blood collection tubes, anticoagulant

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back