izpis_h1_title_alt

Causation of oxidative stress and defense response of a yeast cell model after treatment with orthodontic alloys consisting of metal ions
ID Kovač, Vito (Avtor), ID Bergant, Matic (Avtor), ID Ščančar, Janez (Avtor), ID Primožič, Jasmina (Avtor), ID Jamnik, Polona (Avtor), ID Poljšak, Borut (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,92 MB)
MD5: DFD8753FBF58A30B77E736CADBCE71A1
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2076-3921/11/1/63 Povezava se odpre v novem oknu

Izvleček
Misaligned teeth have a tremendous impact on oral and dental health, and the most efficient method of correcting the problem is orthodontic treatment with orthodontic appliances. The study was conducted to investigate the metal composition of selected orthodontic alloys, the release of metal ions, and the oxidative consequences that the metal ions may cause in the cell. Different sets of archwires, stainless steel brackets, and molar bands were incubated in artificial saliva for 90 days. The composition of each orthodontic material and quantification of the concentration of metal ions released were evaluated. Metal ion mixtures were prepared to determine the occurrence of oxidative stress, antioxidant enzyme defense system, and oxidative damage to proteins. The beta titanium alloy released the fewest metal ions and did not cause oxidative stress or protein damage. The metal ions from stainless steel and the cobalt-chromium alloy can cause oxidative stress and protein damage only at high concentrations. All metal ions from orthodontic alloys alter the activity of antioxidant enzymes in some way. The determined amounts of metal ions released from orthodontic appliances in a simulated oral environment are still below the maximum tolerated dose, and the concentrations of released metal ions are not capable of inducing oxidative stress, although some changes in antioxidant enzyme activity were observed at these concentrations.

Jezik:Angleški jezik
Ključne besede:orthodontic appliance, metal ion release, oxidative stress, ROS, antioxidative defense
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:ZF - Zdravstvena fakulteta
MF - Medicinska fakulteta
BF - Biotehniška fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2022
Št. strani:24 str.
Številčenje:Vol. 11, iss. 1, art. 63
PID:20.500.12556/RUL-136783 Povezava se odpre v novem oknu
UDK:616.314-089.23:546.7:66.094.3.097.8
ISSN pri članku:2076-3921
DOI:10.3390/antiox11010063 Povezava se odpre v novem oknu
COBISS.SI-ID:91359235 Povezava se odpre v novem oknu
Datum objave v RUL:20.05.2022
Število ogledov:501
Število prenosov:73
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Antioxidants
Skrajšan naslov:Antioxidants
Založnik:MDPI
ISSN:2076-3921
COBISS.SI-ID:522976025 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:01.01.2022

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:ortodontski pripomočki, oksidativni stres, kovinski ioni, vpliv na zdravje, antioksidanti

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P3-0388
Naslov:Mehanizmi varovanja zdravja

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0143
Naslov:Kroženje snovi v okolju, snovna bilanca in modeliranje okoljskih procesov ter ocena tveganja

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:J3-2520
Naslov:Ugotavljanje pojava, vzroka in škodljivih učinkov oksidativnega stresa, induciranega zaradi uporabe nesnemnih ortodontskih aparatov

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj