Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Visualization of myocardial strain pattern uniqueness with respect to activation time and contractility : a computational study
ID
Kirn, Borut
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(1,33 MB)
MD5: FE68842713B02DFFA47F168668D5A3B0
URL - Izvorni URL, za dostop obiščite
https://www.mdpi.com/2306-5729/4/2/79
Galerija slik
Izvleček
Speckle tracking echography is used to measure myocardial strain patterns in order to assess the state of myocardial tissue. Because electro-mechanical coupling in myocardial tissue is complex and nonlinear, and because of the measurement errors the uniqueness of strain patterns is questionable. In this study, the uniqueness of strain patterns was visualized in order to revel characteristics that may improve their interpretation. A computational model of sarcomere mechanics was used to generate a database of 1681 strain patterns, each simulated with a different set of sarcomere parameters: time of activation (TA) and contractility (Con). TA and Con ranged from -100 ms to 100 ms and 2% to 202% in 41 steps respectively, thus forming a two-dimensional 41 x 41 parameter space. Uniqueness of the strain pattern was assessed by using a cohort of similar strain patterns defined by a measurement error. The cohort members were then visualized in the parameter space. Each cohort formed one connected component (or blob) in the parameter space; however, large differences in the shape, size, and eccentricity of the blobs were found for different regions in the parameter space. The blobs were elongated along the TA direction (±50 ms) when contractility was low, and along the Con direction (±50%) when contractility was high. The uniqueness of the strain patterns can be assessed and visualized in the parameter space. The strain patterns in the studied database are not degenerated because a cohort of similar strain patterns forms only one connected blob in the parameter space. However, the elongation of the blobs means that estimations of TA when contractility is low and of Con when contractility is high have high uncertainty.
Jezik:
Angleški jezik
Ključne besede:
myocard
,
tissue properties
,
computational modeling
,
signal uniqueness
,
visualization
,
myocardial strain
,
synthetic data
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
MF - Medicinska fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2019
Št. strani:
7 str.
Številčenje:
Vol. 4, iss. 2, art. 79
PID:
20.500.12556/RUL-132251
UDK:
616.1
ISSN pri članku:
2306-5729
DOI:
10.3390/data4020079
COBISS.SI-ID:
34337241
Datum objave v RUL:
19.10.2021
Število ogledov:
735
Število prenosov:
158
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Data
Skrajšan naslov:
Data
Založnik:
MDPI AG
ISSN:
2306-5729
COBISS.SI-ID:
526325273
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:
01.06.2019
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
miokard
,
lastnosti tkiva
,
računalniško modeliranje
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj