izpis_h1_title_alt

Reliability of the weight-bearing ankle dorsiflexion range of motion measurement using a smartphone goniometer application
ID Žunko, Helena (Avtor), ID Vauhnik, Renata (Avtor)

URLURL - Izvorni URL, za dostop obiščite https://peerj.com/articles/11977/ Povezava se odpre v novem oknu
.pdfPDF - Predstavitvena datoteka, prenos (12,48 MB)
MD5: FDC0E1A33BEC0B8E76907A00616AC241

Izvleček
Background. Weight-bearing ankle dorsiflexion range of motion measurement (weight-bearing lunge test) is gaining in popularity because it mimics lower extremity function in daily physical activities. The purpose of the study is to assess the intrarater and the inter-rater reliability of the weight-bearing ankle dorsiflexion range of motion measurement with a flexed knee using a smartphone application Spirit Level Plus installed on an Android smartphone. Methods. Thirty-two young, healthy subjects participated in the study and were measured in four sessions by two examiners. One measurement was taken on each ankle in every session. Eight measurements were taken from each participant. A total of 256 were taken from all the participants. The measurements for the individual subject were repeated no sooner than 24 hours after the first session. In order to assess the reliability, intraclass correlation coefficients (ICC), standard error measurements (SEM) and minimal detectable change (MDC) at the 95% confidence interval were calculated. Results. Statistical data analysis revealed moderate intra-rater reliability for the right ankle (ICC = 0.72, 95% CI [0.49–0.85]) and good intra-rater reliability for the left ankle (ICC = 0.82, 95% CI [0.66–0.91]). Inter-rater reliability is moderate for the right (ICC = 0.73, 95% CI [0.52–0.86]) and the left ankle (ICC = 0.65, 95% CI [0.39–0.81]). Conclusion. The observed method is moderately reliable and appropriate when the main objective is to assess ankle dorsiflexion mobility in weight-bearing when weight-bearing is not contraindicated. The concurrent validity of the Spirit Level Plus application is excellent.

Jezik:Angleški jezik
Ključne besede:ankle, range of motion, reliability, weight-bearing lunge, smartphone goniometer application
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:BF - Biotehniška fakulteta
ZF - Zdravstvena fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2021
Št. strani:Str. 1-13
Številčenje:Vol. 9
PID:20.500.12556/RUL-131185 Povezava se odpre v novem oknu
UDK:615.8:004.382.745
ISSN pri članku:2167-8359
DOI:10.7717/peerj.11977 Povezava se odpre v novem oknu
COBISS.SI-ID:77547011 Povezava se odpre v novem oknu
Datum objave v RUL:23.09.2021
Število ogledov:1770
Število prenosov:203
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:PeerJ
Skrajšan naslov:PeerJ
Založnik:PeerJ Inc.
ISSN:2167-8359
COBISS.SI-ID:31891929 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:22.09.2021

Sekundarni jezik

Jezik:Ni določen
Ključne besede:gleženj, obseg gibanja, zanesljivost, udarci z nosilnostjo, aplikacija goniometer, pametni telefon

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P3-0388
Naslov:Mehanizmi varovanja zdravja

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj