izpis_h1_title_alt

Primerjava različnih rotacijskih viskozimetrov za potrebe živilske industrije
ID Pungertnik, Alen (Author), ID Prislan, Iztok (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (2,37 MB)
MD5: 22EC2FCF9EE2AE8928E9EF56E8F956BC

Abstract
Namen diplomske naloge je bil celostno ovrednotiti delovanje analognega rotacijskega viskozimetra "NDJ-1", uvoženega s Kitajske, s certifikati vprašljive verodostojnosti. V eksperimentih smo se osredotočili na točnost in natančnost v območju 1-100 mPas, ki smo ju določili z uporabo standardnih raztopin saharoze in referenčne naprave Anton Paar ViscoQC 300 – L. Rezultati so pokazali, da skupna negotovost naprave NDJ-1 med 15-100 mPas ustreza intervalu zaupanja 〖CI〗_(95 %)/η=1± 10 %. Med 3-15 mPas je relativna natančnost nizka, zato je za sprejemljiv CI potrebnih več zaporednih meritev. Pod 3 mPas je negotovost previsoka za uporabnost naprave. Negotovosti v območju 100-105 mPas nismo določali, domnevamo pa, da je v tem območju negotovost prav tako ± 10 %. V primerjavi z referenčno napravo smo identificirali tudi druge šibkosti, kot so čas med meritvami (⡥ 16,2 s), nizko število nastavitev hitrosti (4), pomanjkanje avtomatizacije in pomanjkanje vreten za vzorce nizkih viskoznosti. Slabosti bistveno znižajo vsestranskost in uporabnost naprave za nenewtonske tekočine, vendar je naprava za meritve specifičnih analitov gotovo uporabna. Če natančnost, točnost, produktivnost in cena ustrezajo potrebam potencialnega uporabnika ter je primerljiva certificirana rešitev cenovno nedostopna, je nakup lahko upravičen. Pomisleki glede proizvajalcev in posledično certifikatov takšnih naprav onemogočajo direktno prenosljivost naših ugotovitev na naprave enakega izgleda ali imena iz tujih trgov. Iz istih razlogov ocenjujemo napravo za neustrezno kot rešitev za kontrolo točk HACCP.

Language:Slovenian
Keywords:viskozimetrija, viskoznost, rotacijski viskozimeter, živilska industrija
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:BF - Biotechnical Faculty
Place of publishing:Ljubljana
Publisher:[A. Pungertnik]
Year:2021
PID:20.500.12556/RUL-129568 This link opens in a new window
UDC:664.0:532.137
COBISS.SI-ID:74885891 This link opens in a new window
Publication date in RUL:05.09.2021
Views:689
Downloads:93
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Comparison of different rotational viscometer devices for food industry applications
Abstract:
The purpose of this thesis was to fully evaluate the performance of "NDJ-1", an analog rotational viscometer of questionable manufacture and certification imported from China. In experimentation we focused on accuracy and precision in the range 1-100 mPas which we evaluated with the use of standard sucrose solutions and a reference device Anton Paar ViscoQC 300 – L. Results showed a combined uncertainty equal to the confidence interval of 〖CI〗_(95 %)/η=± 10 % η between 15-100 mPas. Low relative precision in the range between 3-15 mPas means that consecutive measurements should be taken to reach an acceptable CI. Under 3 mPas results are not reliable. We speculate that the ± 10 % uncertainty continues through the range of viscosity between 100-105 mPas. In comparing NDJ-1 to the reference device additional weaknesses like high minimum time between measurements (⡥ 16,2 s), low number of sped settings (4), lack of automatization and lack of spindles for low viscosity measurements were identified. Although the weaknesses lower versatility and potential for measurement of non-Newtonian fluids NDJ-1 is certainly a useful device. If precision, accuracy, productivity, and price satisfy the needs of a potential user and no comparable certified solution is affordable purchase may be justified. Concerns over the manufacturers of such devices and by extension their certificates make our results non-directly-transferable to devices of similar look and name. Thus, we deem NDJ-1 inappropriate for monitoring HACCP.

Keywords:viscometry, viscosity, rotational viscometer, food industry

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back