izpis_h1_title_alt

Višinska referenčna ploskev (SLO_VRP2016/Koper) na območju Ljubljane : magistrsko delo št.: 113/II. GIG
ID Brglez, Robert (Author), ID Kuhar, Miran (Mentor) More about this mentor... This link opens in a new window, ID Koler, Božo (Comentor)

.pdfPDF - Presentation file, Download (11,81 MB)
MD5: F7671144D88EB78F115C2725A3F5DF4F

Abstract
V magistrskem delu smo za potrebe kontrole kakovosti nove višinske referenčne ploskve na območju Ljubljane izbrali določeno število reperjev mestne nivelmanske mreže in reperjev državne nivelmanske mreže (novi 1. red) in jih razporedili po območju Ljubljane tako, da tvorijo približno celično mrežo velikosti 1 x 1 kilometer. Na teh reperjih smo s kombinacijo RTK-GNSS meritev in geometričnim nivelmanom določili vrednosti geoidnih višin. Te smo primerjali z interpoliranimi vrednosti iz uradnega modela višinske referenčne ploskve. Primerjavo smo opravili tudi z višinami teh točk v starem višinskem sistemu SVS2000 in starem modelu geoida SLO_AMG2000. Predstavili smo teoretično osnovo za kontrolo kakovosti višinske referenčne ploskve, potek izbora ustreznih reperjev ter grafično in numerično analizirali pridobljene rezultate. Prikazali smo razlike med izmerjenimi in interpoliranimi geoidnimi višinami iz novega modela geoida (SLO_VRP2016/Koper) za obravnavano območje Ljubljane ter jih interpretirali. Rezultati primerjave na novi višinski referenčni ploskvi SLO_VRP2016/Koper so pokazali, da so na obravnavanem območju Ljubljane povprečne razlike geoidnih višin -1,6 cm. V ta izračun je bilo vključenih 56 izmerjenih reperjev. Maksimalna vrednost razlike geoidnih višin je 4,0 cm na reperju 22/2, minimalna vrednost pa % 9,1 cm na reperju 40/23. Ugotovili smo, da se SLO_VRP2016/Koper dobro ujema z vrednostmi geoidnih višin, ki so določene z meritvami.

Language:Slovenian
Keywords:geodezija, magistrska dela, GIG, kvazigeoid, višinska referenčna ploskev, geoidna višina, GNSS višinomerstvo, elipsoidna višina, interpolacija, kakovost, SLO_VRP2016/Koper, SLO_AMG2000
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[R. Brglez]
Year:2020
Number of pages:X, 41 str. 5 str. pril.
PID:20.500.12556/RUL-120604 This link opens in a new window
UDC:528.235(497.4)(043.3)
COBISS.SI-ID:37525763 This link opens in a new window
Publication date in RUL:23.09.2020
Views:2205
Downloads:244
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Height reference surface (SLO_VRP2016/Koper) on the area of Ljubljana : master thesis no.: 113/II. GIG
Abstract:
In the master thesis we selected a certain number of benchmarks of the city leveling network and benchmarks of the state leveling network (new 1st order) for the needs of quality control of the new height reference surface on the area of Ljubljana distributed over the area so that they form approximately a cell network of size 1 x 1 kilometer. On these benchmarks, we determined the values of geoid heights with a combination of RTK-GNSS measurements and geometric leveling. These were compared with the interpolated values from the official model of the height reference surface. We also made a comparison with the heights of these points in the old vertical system SVS2000 and the old model of the geoid SLO_AMG2000. We presented the theoretical basis for quality control of the height reference surface, the selection process of appropriate benchmarks and graphically and numerically analyzed the obtained results. We presented the differences between the measured and interpolated geoid heights from the new geoid model (SLO_VRP2016 / Koper) for the considered area of Ljubljana and interpreted them. The results of the comparison on the new height reference surface SLO_VRP2016 / Koper showed that in the considered area of Ljubljana the average differences of geoid heights are -1.6 cm. 56 measured benchmarks were included in this calculation. The maximum value of the difference in geoid heights is 4.0 cm on the benchmark 22/2, and the minimum value is 9.1 cm on the benchmark 40/23. We found that SLO_VRP2016 / Koper matches well with the values of geoid heights, which are determined by measurements.

Keywords:geodesy, master thesis, quasi-geoid, height reference surface, geoid height, GNSS altimetry, ellipsoidal height, interpolation, quality, SLO_VRP2016/Koper, SLO_AMG2000

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back