izpis_h1_title_alt

Odprava zagonskih vibracij ventilatorja z uvedbo metode DMAIC
ID Gaberšček, Anže (Author), ID Kramar, Davorin (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (3,79 MB)
MD5: A7DED4E6B27FFE3F7333AC17B92E8E62

Abstract
V diplomskem delu je predstavljena odprava zagonskih vibracij aksialnega ventilatorja z uvedbo DMAIC metode. Zaradi številnih reklamacij kupcev ter nepotrebnih dodelav v montažnem procesu predstavljajo vibracije velik problem. V teoretičnem delu so predstavljene osnove obravnavanega aksialnega ventilatorja. Podrobneje je opisana metodologija DMAIC ter nekatera orodja, ki so uporabljena v posameznih fazah. V praktičnem delu pa je predstavljen celoten potek projekta odprave zagonskih vibracij aksialnega ventilatorja. Glavni del predstavljajo testi hipotez, ki nam omogočajo definiranje izvirnih vzrokov za nastale vibracije. Na podlagi testov hipotez so definirane in uvedene najprimernejše izboljšave v procesu in na samem izdelku. V zaključku je prikazana primerjava starega in novega procesa s pomočjo kontrolnih kart ter sposobnosti procesa. Prikazana je tudi primerjava med začetnim, ciljnim in dejanskim stanjem reklamacij kupca in stroškov dodatnih ur.

Language:Slovenian
Keywords:DMAIC, 6 - Sigma, aksialni ventilator, vibracije, statistična analiza hipotez
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[A. Gaberšček]
Year:2020
Number of pages:XXII, 49 str.
PID:20.500.12556/RUL-118834 This link opens in a new window
UDC:519.6:621.6.057(043.2)
COBISS.SI-ID:29213443 This link opens in a new window
Publication date in RUL:01.09.2020
Views:772
Downloads:119
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Elimination of fan starting vibrations by introducing the DMAIC methodology
Abstract:
The diploma thesis presents the elimination of starting vibrations of an axial fan with the introduction of the DMAIC methodology. Vibrations are a big problem due to numerous customer complaints and unnecessary finishing touches in the assembly process. In the theoretical part, the basics of the considered axial fan are presented. The DMAIC methodology and some of the tools used in each phase are described in details. In the practical part, the entire course of the project of eliminating the starting vibrations of the axial fan is presented. The main part is the hypothesis tests, which allow us to define the root causes of the resulting vibrations. Based on the hypothesis tests, the most appropriate improvements in the process and on the product itself are defined and introduced. In the conclusion, a comparison of the old and the new process is shown with the help of control charts and process capability. A comparison between the initial, target and actual status of customer complaints and the cost of additional hours is shown.

Keywords:DMAIC, 6 - Sigma, axial fan, vibration, statistical hypothesis testing