izpis_h1_title_alt

Ponovljivost in povezanost testov aktivni dvig stegnjene noge in barvne vidne analogne lestvice pri nosečnicah
ID Stanković, Manca (Author), ID Šćepanović, Darija (Author), ID Jakovljević, Miroljub (Author)

.pdfPDF - Presentation file, Download (1,70 MB)
MD5: 4A544359959C36831F27F8169AA76375
URLURL - Source URL, Visit http://www.dlib.si/details/URN:NBN:SI:doc-ZQ0K9YII This link opens in a new window

Abstract
Uvod: Če povečana laksnost ligamentov v nosečnosti ni kompenzirana s spremenjenim nevromotoričnim nadzorom, lahko pride do bolečine v medenici, ki jo lahko ocenjujemo z barvno vidno analogno lestvico (angl. Colour Visual Analogue Scale – CVAS) ali/in testom aktivnega dviga stegnjene noge (Active Straight Leg Raise – ASLR). Metode: V raziskavo je bilo vključenih 60 nosečnic, ki so bile v 12. tednu nosečnosti ali več. Z omenjenima testoma smo ocenjevali bolečino v medeničnem obroču med nosečnostjo. Vsako ocenjevanje smo opravili dvakrat. Rezultati: Pearsonov korelacijski koeficient je pokazal dobro povezanost med CVAS in ASLR tako prve (r = 0,755) kot tudi druge meritve (r = 0,808). Razlika med prvo in drugo oceno s CVAS je bila pomembna (p = 0,03), nasprotno pa med prvo in drugo meritvijo z ASLR ni bilo pomembnih razlik. Ugotovljena je bila visoka ponovljivost ASLR (IKK = 0,96). Zaključki: ASLR-test je veljaven, zanesljiv in občutljiv in pomeni močno konkurenco vsem drugim kliničnim testom za oceno bolečine v medeničnem obroču pri nosečnicah.

Language:Slovenian
Keywords:bolečina v medeničnem obroču, nosečnost, ocenjevanje bolečine, lestvice
Typology:1.01 - Original Scientific Article
Organization:ZF - Faculty of Health Sciences
Year:2014
Number of pages:Str. 1-6
Numbering:Letn. 22, št. 1
PID:20.500.12556/RUL-114741 This link opens in a new window
UDC:615.82/.84-055.26:616-009.7
ISSN on article:1318-2102
URN:URN:NBN:SI:doc-ZQ0K9YII
COBISS.SI-ID:4695659 This link opens in a new window
Publication date in RUL:06.03.2020
Views:1082
Downloads:223
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Fizioterapija
Shortened title:Fizioterapija
Publisher:Društvo fizioterapevtov Slovenije, Društvo fizioterapevtov Slovenije, Združenje fizioterapevtov Slovenije
ISSN:1318-2102
COBISS.SI-ID:30074880 This link opens in a new window

Secondary language

Language:English
Title:Repeatability and correlation of Active Straight Leg Raise and Colour Visual Analogue Scale in pregnant women
Abstract:
Introduction: If increased laxity of ligaments during pregnancy is not compensated with changed neuro-motor control, this may lead to pelvic girdle pain, which we can assess with Colour Visual Analogue Scale (CVAS) and Active Straight Leg Raise (ASLR) test. Methods: Sixty expectant mothers were included who were twelve or more weeks pregnant. The pelvic girdle pain was assessed with the mentioned two tests. Each assessment was repeated twice. Results: Pearson’s correlation coefficient showed good correlation between the CVAS and ASLR test in the first (r = 0.755) as well as the second measurement (r = 0.808). The difference between the first and the second measurement with CVAS were significant (p = 0.03), while there were no significant differences between the first and the second measurement with the ASLR test. ASLR test also showed high repeatability (ICC=0.96). Conclusions: The ASLR test is valid, reliable and sensitive enough and presents a strong competition to all other clinical tests for the pelvic girdle pain assessment in pregnant women.

Keywords:pelvic girdle pain, pregnancy, pain assessment, scales

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back