The influence of temperature, disinfection and water softening of drinking water on the multiplication of Legionella pneumophila
ID
Godič Torkar, Karmen
(
Avtor
),
ID
Oder, Martina
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(607,47 KB)
MD5: B20D3F20E26C5D50BDAFCFBE36F3AE08
Galerija slik
Izvleček
The influence of temperature, disinfectant and water softener for drinking water preparation on the bacterial growth of Legionella pneumophila was examined.The optimal temperature for bacterial growth was 36 °C. At the incubation temperature of 15 °C the multiplying of bacteria slowed down, as confirmed by the bacteriostatic effect of this temperature. The number of bacteria was after the first 24 h of incubation at 55 °C reduced by more than 6 log in comparison to the culture at 36 °C. After 10 minutes of exposure to the disinfectant dichloroisocyanuric acid, the number of bacteria in the culture decreased for 1.4 log CFU mL-1, followed by an intensive growth immediately after the disinfectant degradation. The number of bacteria was up to 72 hours incubation even higher than in the control sample without a disinfectant, and then the number in both samples equalled at approximately 7.3 log CFU mL-1. Sodium polyphosphate used as a water softener stimulated the bacterial growth. The largest difference in growth was observed after 72 h of incubation, which was 1.9 log CFU mL-1 higher in samples with sodium polyphosphate in comparison to those without the softener.
Jezik:
Angleški jezik
Ključne besede:
Legionella pneumophila
,
growth curve
,
temperature
,
water softener
,
disinfectant
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
ZF - Zdravstvena fakulteta
Leto izida:
2018
Št. strani:
Str. 34-42
Številčenje:
Vol. 12, no. 1
PID:
20.500.12556/RUL-112967
UDK:
614.48:579.841
ISSN pri članku:
1854-0678
COBISS.SI-ID:
5590123
Datum objave v RUL:
26.11.2019
Število ogledov:
1376
Število prenosov:
220
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Sanitarno inženirstvo
Založnik:
Inštitut za sanitarno inženirstvo, Zbornica sanitarnih inženirjev Slovenije
ISSN:
1854-0678
COBISS.SI-ID:
216969216
Licence
Licenca:
CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:
Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Začetek licenciranja:
26.11.2019
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj