Eksperimentalna izokinetična naprava za testiranje oseb in športnikov
ID Mikelj, Martin (Author), ID Kunc, Robert (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (4,13 MB)
MD5: 275BAD079DE6C830BA1CEB0E2FCF87E1

Abstract
Opravljeno je bilo validiranje eksperimentalne izokinetične naprave, imenovane iMoment, za testiranje poškodovanih oseb in športnikov, ki uporabniku omogoča celovito testiranje sposobnosti, razgibavanja in kondicijske pripravljenosti ter sistematično beleženje rezultatov. Pred začetkom splošne uporabe smo preverili pravilnost oziroma odstopanje meritev od pravih vrednosti ter njihovo ponovljivost. Validiranja smo se lotili s protokolom, ki je sestavljen iz statične in dinamične meritve. Dinamična meritev se deli še na CPM (ang. Continuous Passive Movement) in izokinetično meritev. Podatke, pridobljene s kalibracijskim merilnim sistemom, sem obdelal s programom Excel in jih primerjal z meritvami naprave iMoment. Iz rezultatov so razvidna odstopanja hitrosti in momenta od naših kalibracijskih vrednosti. Poiskal sem vzroke za odstopanja ter predlagal popravke za izboljšanje naprave iMoment in samega merilnega sistema za nadaljnja testiranja.

Language:Slovenian
Keywords:izokinetične naprave, telesna učinkovitost, rehabilitacija, iMoment, kineziologija
Work type:Final paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[M. Mikelj]
Year:2019
Number of pages:XV, 40 f., [10] f. pril.
PID:20.500.12556/RUL-110184 This link opens in a new window
UDC:612.76:616-001:531.78(043.2)
COBISS.SI-ID:16936987 This link opens in a new window
Publication date in RUL:12.09.2019
Views:1875
Downloads:528
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Experimental isokinetic device for testing people and athletes
Abstract:
Validation of an experimental isokinetic device called iMoment for testing injured people and athletes has been carried out. The device must allow the user to perform comprehensive testing of abilities, stretching and fitness, and to systematically record results. Prior to the commencement of general use, we checked the accuracy deviation of the measurements from the true values and their repeatability. Validation was undertaken with a protocol consisting of static and dynamic measurement. Dynamic measurement was further divided into Continuous Passive Movement (CPM) and isokinetic measurement. The data obtained with the calibration measuring system were processed with Excel and compared with the measurements of the iMoment device. The results showed variations in speed and torque from our calibration values. The diploma work examined possible reasons for the discrepancies and suggested improvements to the iMoment device and the measurement system itself for further testing.

Keywords:isokinetic devices, physical performance, rehabilitation, iMoment, kinesiology