izpis_h1_title_alt

Povezava med svetlobnim in toplotnim udobjem na primeru generičnega poslovnega prostora : diplomska naloga
ID Kavka, Urban (Author), ID Košir, Mitja (Mentor) More about this mentor... This link opens in a new window, ID Pajek, Luka (Comentor)

.pdfPDF - Presentation file, Download (4,71 MB)
MD5: DD760AF785B68B0929F8D98C778E4F13
.pdfPDF - Appendix, Download (3,11 MB)
MD5: 4567D63B7410DC0FCFF6A12C2DE8F838

Abstract
V diplomski nalogi sem analiziral notranje delovno okolje v generičnem poslovnem prostoru, pri čemer sem se osredotočil tako na svetlobno kot tudi na toplotno udobje. Z uporabo programskega orodja Comfen sem raziskoval vpliv velikosti in tipa zasteklitve. Omejil sem se na situacijo brez uporabe senčil in svetlobnih polic. Analiziral sem 5 različnih velikosti odprtine in 4 različne tipe zasteklitve. Namen diplomske naloge je bilo poiskati povezavo med svetlobnim in toplotnim udobjem, ki bi omogočala optimalno kombinacijo teh dveh parametrov tako, da bi imela oba parametra enako težo. Z uporabo izračunov poteka dnevne osvetljenosti na povprečni dan posameznega letnega časa sem določil vrednosti uporabne dnevne osvetljenosti, t.i. UDI. Simulacija osvetljenosti je bila napravljena v dveh referenčnih točkah. Za toplotno udobje nam programsko orodje Comfen že sam po sebi ponuja izračune dnevnega poteka toplotnega udobja na povprečni dan posameznega letnega časa v obliki faktorja PPD. Rezultate sem predstavil kot točke na koordinatnem sistemu, kjer je bilo na x-osi toplotno udobje in na y-osi svetlobno udobje. Ker sem analiziral 20 različnih scenarijev v vseh štirih letnih časih in v dveh različnih simulacijskih točkah, sem imel 160 različnih točk. Nato sem rezultate združil z dveh simulacijskih točk v enotni prostor in časovno obdobje celega leta. S pomočjo uporabe statistične vrednosti geometrijske sredine sem prišel do rezultatov skupnega udobja za celotno leto. Tako sem pridobil zgolj 20 različnih vrednosti, izmed katerih sem s primerjavo določil najbolj optimalno izbiro velikosti in tipa zasteklitve. Rezultate sem komentiral na podlagi vhodnih podatkov in omejitev ter podal vpogled v nadaljno analizo izbranega problema.

Language:Slovenian
Keywords:svetlobno udobje, toplotno udobje, UDI, PPD, generični poslovni prostor, zasteklitev
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Publisher:U. Kavka]
Year:2019
PID:20.500.12556/RUL-108918 This link opens in a new window
UDC:699.8:72.054(043.2)
COBISS.SI-ID:8898401 This link opens in a new window
Publication date in RUL:03.08.2019
Views:1530
Downloads:415
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Connection between visual and thermal comfort in generic office : graduation thesis
Abstract:
In my diploma thesis I analysed indoor work environment in generic business premises, within which I focused both on visual as well as thermal comfort. Using the software tool Comfen, I researched how size, type of window and non-use of shadows or light shelfs affect results. I analysed 5 different sizes and 4 different types of windows. The purpose of this thesis was to find a connection between visual and thermal comfort, which would provide us with the optimal comparisson for both parameters. I defined values of useful daylight illuminance, known as well as UDI, by using calculation of hourly illuminance on average day of specific season. Simulation of illuminance was made in two reference points. Comfen gives us results for thermal comfort as calculations of predicted percentage of dissatisfied users, PPD, throughout the average day of specific season. I collected the results as points in coordinate system, where x-axis is represented as thermal comfort and y-axis as visual comfort. Due to the fact that I analysed 20 different scenarios in 2 different reference points for 4 seasons, my coordination had in total 160 points. In order to make the result more legible I combined the results as points for a whole year and business premises as one entity. In my research I used geometric mean as a tool to combine values of both visual and thermal comfort into one representative value. That way I got for my final comparison only 20 results. At the end I defined the optimal scenario, showing us which size and type of window give us the best results taking into consideration both . I comment on the results based on my input data, presumptions and restrictions and add a perspective on possible further analysis and research of this problem.

Keywords:visual comfort, thermal comfort, UDI, PPD, office, glazing

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back