izpis_h1_title_alt

Ponovljivost in zanesljivost goniometričnih meritev pasivnega obsega gibljivosti kolenskega sklepa : diplomsko delo
ID Janežič, Patricija (Author), ID Jakovljević, Miroljub (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (640,27 KB)
MD5: F87B6D787A9FAF6AC64B08A08157056D

Abstract
Uvod: Najpogostejši način merjenja gibljivosti sklepov so goniometrične meritve. Meritve izvajamo navadno z univerzalnim goniometrom. Izvajamo jih z namenom pridobivanja objektivnih meritev o gibljivosti posameznega sklepa. Ker meritve običajno izvajajo različni terapevti, je pomembna zanesljivost posameznega preiskovalca. Namen: Namen diplomskega dela je bil ugotoviti ponovljivost in zanesljivost pasivnih goniometričnih meritev obsega gibljivosti kolenskega sklepa. Metode dela: V raziskavo je bilo vključenih 30 zdravih preiskovank starih med 18 in 25 let. Merjenja so potekala v dveh sejah s 48 urnim vmesnim premorom. Razlike med meritvami smo vrednotili z analizo variance za ponovljene meritve (p≤0,05), če je bila razlika med meritvami pomembna smo opravili Bonferroni »post hoc« test (p≤0,05). Ponovljivost in zanesljivost smo vrednotili z intraklasnim koeficientom korelacije (ICC 2,1). Izračunali smo tudi najmanjšo dejansko razliko. Za obdelavo podatkov smo uporabili statistični program MedCalc Statistical Software version 14.12.0 (MedCalc Software bvba, Ostend, Belgium) Microsoft Excel (verzija 2013, Microsoft Corporation, Redmond, ZDA). Rezultati: Tako v prvi, kot v drugi seji med zaprednimi meritvami začetnega in končnega položaja ni bilo pomembnih razlik. Ponovljivost testa, je bila visoka. Najvišji ICC smo izračunali pri meritvah ekstenzije (ICC = 0,935), najnižjega pa pri prvih meritvah fleksije (ICC = 0,808) v prvi sejii. Povprečne vrednosti meritev med prvo in drugo sejo so se pomembno ralikovale le pri meritvah ekstenzije (p=0,013). Vrednosti ICC so bile za vse zmerjene spremenljivke nad 0,8, kar kaže na odlično zanesljivost metode. Zanesljivost je bila boljša pri meritvahfleksij (ICC = 0,925). Najmanjša dejanska razlika je bila pri meritvah ekstenzije 4,3̊, pri meritvah fleksije 4,0̊ in za celoten obseg giba 6,0̊. Razprava in zaključek: Goniometrične meritve kolenskega sklepa so ponovljive in zanesljive, nekoliko bolj pri meritvah fleksije kot pri merjenju pasivnega giba ekstenzije kolenskega sklepa. Zanesljivost je primerljiva z drugimi, že izvedenimi raziskavami. Najmanjša zaznana sprememba je prav tako kaže na odlično zanesljivost. V primerjavi z že izvedenimi raziskavami, je najmanjša zaznana sprememba v naši raziskavi še manjša.

Language:Slovenian
Keywords:goniometrične meritve, zanesljivost preiskovalca, pasivna sklepna gibljivost
Work type:Bachelor thesis/paper
Organization:ZF - Faculty of Health Sciences
Year:2018
PID:20.500.12556/RUL-105809 This link opens in a new window
COBISS.SI-ID:5571947 This link opens in a new window
Publication date in RUL:18.12.2018
Views:2670
Downloads:499
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Repeatability and reliability of knee passive range of motion goniometric measurements : diploma work
Abstract:
Introduction: The most common way of measuring joint mobility is goniometric measurements. Measurements are performed with a universal goniometer. We carry them out in order to obtain objective measurements of the flexibility of a particular joint. Because measurements are usually conducted by different therapists, the intratester reliability is very important. Purpose: The purpose of the diploma thesis was to identify the repeatability and reliability of passive goniometric measurements of the range of flexibility of the knee joint. Methods: The study involved 30 healthy subjects aged between 18 and 25 years. Measurements were made in two sessions with a 48 hours intermittent break. The differences between the measurements were assessed by the analysis of the variance for repeated measurements (p≤0.05), if the difference between the measurements was significant, we performed the "post hoc" test of Bonferroni (p≤0.05). Repeatability and reliability were assessed by the intraclassic correlation coefficient (ICC 2.1). We also calculated the lowest real difference. MedCalc Statistical Software version 14.12.0 (MedCalc Software bvba, Ostend, Belgium) and Microsoft Excel (version 2013, Microsoft Corporation, Redmond, USA) was used to process data. Results: Thus, in the first, as in the second session, there were no significant differences between the initial measurements of the initial and final positions. The repeatability of the test was high. The highest ICC was calculated for extensions measurements (ICC = 0.935) and the lowest in the first measurements of flexion (ICC = 0.808) in the first session. The average values of measurements between the first and frugo sessions were important only for extensions measurements (p = 0.013). ICC values for all measured variables above 0.8, indicating the excellent reliability of the method. Reliability was better in the measurement of fleshes (ICC = 0.925). The slightest actual difference was in the measurements of the extension of 4.3°, in the measurements of the flexion 4.0° and for the entire range of movement 6.0°. Discussion and conclusion: Goniometric measurements of the knee joint are repeatable and reliable, somewhat more in the measurement of flexion than in the measurement of the passive motion of the knee joint extension. Reliability is comparable to other studies already carried out. The smallest detected change also indicates excellent reliability. Compared to already performed studies, the smallest reliable change in our study is even lower.

Keywords:goniometric measurements, intratester reliability, passive joint mobility

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back