Abstract
V magistrski nalogi smo se dotaknili teme o kakovosti električne energije v specifičnem industrijskem okolju. Delo obsega obdelavo osnovne tematike, kot tudi praktični prikaz izvedbe meritev kakovosti električne energije v določenem delu industrijskega omrežja za potrebe izvedbe simulacije. Meritev smo izvajali pri različnih obremenitvah, ter tako pridobili podatke za več različnih scenarijev. Sledila je obdelava podatkov ter izvedba simulacijskega omrežja v programskem paketu PSCAD. Pri izvedbi simulacije smo se osredotočili na vpliv priključitve paralelnega aktivnega filtra na bremensko zbiralko. Opazovali smo, kaj nam to prinese s stališča kakovosti električne energije. Sledilo je testiranje realnega aktivnega harmonskega filtra v transformatorski postaji. Tukaj smo s pomočjo analizatorjev moči ugotovili vpliv filtra na sistemu in pregledali njegove učinke.

Language:Slovenian
Keywords:poraba električne energije, industrijsko omrežje, kakovost električne energije, skupno harmonsko popačenje, aktivni harmonski filter.
Work type:Master's thesis/paper
Organization:FE - Faculty of Electrical Engineering
Year:2018
PID:20.500.12556/RUL-104082 This link opens in a new window
Publication date in RUL:04.10.2018
Views:1412
Downloads:444
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Harmonics compensation in an industrial-consumer’s network by means of an active filter
Abstract:
This master's degree thesis deals with electricity quality in a specific industrial enviroment. At the beginning, a review of basic topics is presented with the example of electicity quality measurement at a certain part of the industrial network for the needs of the simulation. The measurements were performed at different loads in order to obtain data for several different scenarios. Afterwards, the data processing and implementation of the simulation network in the PSCAD software package are presented. Influence of the connection of the parallel active filter to the load collector was the simulation’s focus, as well as the contribution, made to electricity quality. Lastly, testing of a real active harmonic filter in a transformer station was done. Effects of filter in the system were examined with the help of power analyzers.

Keywords:power consumption, industrial electrical network, quality of electricity, total harmonic distortion, active harmonic filter.