Your browser does not allow JavaScript!
JavaScript is necessary for the proper functioning of this website. Please enable JavaScript or use a modern browser.
Open Science Slovenia
Open Science
DiKUL
slv
|
eng
Search
Browse
New in RUL
About RUL
In numbers
Help
Sign in
Vpliv oblike okolčja in postavitve endoproteze kolka na izpah umetne glavice ter ortotična pooperativna oskrba : diplomsko delo
ID
Kaiba, Tina
(
Author
),
ID
Kralj-Iglič, Veronika
(
Mentor
)
More about this mentor...
,
ID
Divjak, Mojca
(
Comentor
),
ID
Tomaževič, Matevž
(
Comentor
)
PDF - Presentation file,
Download
(1,01 MB)
MD5: BE92B296C98DC43ED1DFDB162D92C842
Image galllery
Abstract
Uvod: Artroplastika ter sklepna endoprotetika je najpogostejša in zelo uspešna operativna tehnika. Glavni razlogi za to operacijo so osteoartroza, zlom vratu stegnenice pri starostniku ter aseptična nekroza glavice stegnenice. Pooperativni izpah oziroma luksacija kolčne endoproteze je pogosta komplikacija, ki se lahko pojavi po vstavitvi totalne kolčne endoproteze. Verjetnost izpaha kolčne endoproteze je 2% (Dargel et al., 2014) v prvem letu po operaciji, 6% po dvajsetih letih (Berry et al., 2005), v primeru menjave kolčne endoproteze pa verjetnost naraste na 28% (Dargel et al., 2014). Namen: Namen diplomskega dela je ugotoviti, ali imajo kolčne proteze z neugodno porazdelitvijo kolčnega sklepnega tlaka povečano tveganje za izpah. Metode dela: V raziskavi smo primerjali skupino protez, pri katerih je prišlo do izpaha endoproteze (testna skupina) in skupino protez, ki so bile funkcionalne vsaj 10 let (kontrolna skupina). Kontrolna skupina je vsebovala 94 endoprotez 77 pacientov, testno skupino pa je sestavljalo 61 endoprotez 61 pacientov z vstavljenimi kolčnimi endoprotezami. Od tega je bilo šest parcialnih endoprotez in 55 totalnih endoprotez. Uporabili smo metodo HIPSTRESS za določanje porazdelitve kontaktnega kolčnega tlaka pri stoji na eni nogi. Za vstopne podatke smo uporabili geometrijske parametre medenice in okolčja, ki smo jih odčitali iz standardnih anteroposteriornih (AP) rentgenskih slik. S pomočjo geometrijskih parametrov smo v nadaljevanju študije izračunali tudi biomehanske parametre (velikost in smer rezultantne kolčne sklepne sile, lego pola tlaka in največji tlak na obremenjeni površini) z uporabo programa HIPSTRESS. Pri opisu že obstoječih znanj smo uporabili deskriptivno metodo in pregled literature. Rezultati: Pri primerjavi parametrov se pojavijo statistično pomembne razlike med testno in kontrolno skupino v velikosti rezultantne kolčne sile in v največjem kolčnem tlaku, ki sta bila normalizirana s telesno težo. Razlike so bile statistično pomembne, parametri pa manj ugodni v testni skupini. Razprava in zaključek: Ugotovili smo, da je imela populacija protez, pri katerih je prišlo do izpaha, manj ugodno porazdelitev tlaka, ki tudi pri stoji na eni nogi poriva glavico lateralno. Matematični modeli so primerni za načrtovanje optimalne lege proteze.
Language:
Slovenian
Keywords:
kolčne endoproteze
,
izpah
,
Hipstress
,
geometrijski parametri medenice in okolčja
,
pooperativne ortoze za kolk
Work type:
Bachelor thesis/paper
Organization:
ZF - Faculty of Health Sciences
Year:
2018
PID:
20.500.12556/RUL-103803
COBISS.SI-ID:
5496427
Publication date in RUL:
26.09.2018
Views:
2515
Downloads:
417
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Copy citation
Share:
Secondary language
Language:
English
Title:
The influence of the shape of hips and pelvis and the position of hip endoprosthesis on the dislocation of the femoral head and orthotic post-operative care : diploma work
Abstract:
Introduction: Arthroplasty and endoprosthetics is a new and a very successful operative technique. The main indications for arthroplastic surgery are osteoarthritis, fracture of the femoral neck in geriatric patients and aseptic necrosis of the femoral head. Postoperative dislocation of the total hip endoprosthesis is a complication that can occur after the surgery. The possibility for the dislocation is 2% (Dargel et al, 2014) in the first year and 6% (Berry et al, 2005) in the first twenty years. If the hip endoprosthesis has to be replaced, the risk for dislocation increases to 28% (Dargel et al, 2014). Purpose: The purpose of this diploma thesis is to find out whether the hip endoprostheses with poor hip joint pressure distribution are more susceptible to dislocation. Methods: The present research compared a group of unstable hip endoprostheses that underwent dislocation (experimental group) and hip endoprostheses that were functional for at least 10 years (control group). The control group with stable hips consisted of 94 endoprostheses of 77 patients. In the experimental group there were 61 hip endoprostheses from 61 patients. In this group there were 6 partial hip endoprostheses and 55 total hip endoprostheses. The HIPSTRESS method was used to determine the hip stress distribution in one-legged stance. The geometrical parameters of the hip and pelvis were used as input data. These parameters were retrieved from standard anteroposterior (AP) radiograms. The geometrical parameters enabled the calculation of biomechanical parameters (the size and the direction of the resultant hip force, the location of the stress pole, and the peak stress on the weight-bearing area) by using the HIPSTRESS program. The descriptive method with a literature review was used to describe the existing knowledge. Results: The differences between the experimental and the control group occurred in the size of the resultant hip force and in the maximal hip stress which were normalized to body weight. The differences were statistically significant and the parameters were less favourable in the experimental group. Discussion and conclusion: It has been found that the population with the dislocated endoprostheses had a less favourable stress distribution. This means that even in one-legged stance it pushes the femoral head laterally. The mathematical models are suitable for planning the optimal position of the endoprosthesis.
Keywords:
hip endoprosthetics
,
dislocation
,
Hipstress
,
geometrical parameters of hip and pelvis
,
postoperative hip orthosis.
Similar documents
Similar works from RUL:
Similar works from other Slovenian collections:
Back