izpis_h1_title_alt

Vzpostavitev merilnega mesta za merjenje fiziološkega vpliva infrazvoka na človeško telo
ID MAGAJNE, ALEŠ (Author), ID Beguš, Samo (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (2,94 MB)
MD5: 5837E2BFE20F09FEB633D507FF54739F

Abstract
V tej nalogi je predstavljena izgradnja merilnega sistema za merjenje fiziološkega odziva človeškega telesa na čiste tone zelo nizkih frekvenc. Cilj naloge je zdravim prostovoljcem predvajati tone v področju infrazvoka in na meji slišnega praga na eno uho in na obe ušesi, ter med poslušanjem opravljati meritve fizioloških parametrov, kot sta prevodnost kože in srčni utrip. Za predvajanje zvoka je uporabljen osebni računalnik s programsko opremo LabView, ki generira signal, ki se prek zvočne kartice in nizkotonskega zvočnika predvaja preko slušalk osebi v gluhi sobi. Za prenos zvoka iz kontrolne v gluho sobo so uporabljene polietilenske cevke. Za merjenje fizioloških parametrov je uporabljen modul Biopac.

Language:Slovenian
Keywords:infrazvok, fiziološki parametri, LabView, Biopac, EARS2
Work type:Bachelor thesis/paper
Organization:FE - Faculty of Electrical Engineering
Year:2018
PID:20.500.12556/RUL-103743 This link opens in a new window
Publication date in RUL:24.09.2018
Views:1056
Downloads:326
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Development of a measuring system set-up for measuring the physiological influence of the infrasound on the human body
Abstract:
In this paper, the construction of a measuring system for measuring the physiological response of the human body to pure tones at very low frequencies is presented. The goal of the task is to give healthy volunteers a tone in the infrasound frequency range and at the edge of the hearing threshold to one ear and to both ears, and to perform measurements of physiological parameters such as conductivity of the skin and heart rate while listening. For audio playback, a PC with a LabView software is used, which generates a signal that is played through the sound card and the subwoofer into headset of person in a anechoic chamber. Polyethylene tubes are used to transfer sound from the control room to the anechoic chamber. To measure physiological parameters, the Biopac module is used.

Keywords:infrasound, physiological parameters, LabView, Biopac, EARS2

Similar documents