Details

Vpliv hitrostnih razmer na vstopu na karakteristiko radialnega ventilatorja
ID Pipp, Peter (Author), ID Hočevar, Marko (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (14,07 MB)
MD5: 5CC8726B8F2B0093720C765B029B103D

Abstract
V sušilnikih perila želimo z ventilatorjem doseči velike pretoke in tlake. Velik pretok omogoča boljše prepihovanje perila v bobnu in s tem bolj učinkovit ter krajši čas sušenja. Vpliv vstopnikov na karakteristiko radialnega ventilatorja smo določili na merilni postaji, kjer smo izmerili delovne karakteristike in krivulje izkoristka ter z anemometrom na vročo žičko izmerili hitrostno polje na vstopu ventilatorja. Iz rezultatov smo ugotovili izboljšanje zmogljivosti in učinkovitosti merjenega ventilatorja v primeru obrnjenega vstopnika glede na privzet položaj le-tega v sušilnem stroju perila.

Language:Slovenian
Keywords:sušilnik perila, radialni ventilator, merilna postaja, vročežična anemometrija, karakteristika ventilatorja, hitrostno polje
Work type:Master's thesis
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Publisher:[P. Pipp]
Year:2018
PID:20.500.12556/RUL-102738 This link opens in a new window
UDC:648.33:533.6(043.2)
COBISS.SI-ID:16425755 This link opens in a new window
Publication date in RUL:07.09.2018
Views:2627
Downloads:430
Metadata:XML DC-XML DC-RDF
:
PIPP, Peter, 2018, Vpliv hitrostnih razmer na vstopu na karakteristiko radialnega ventilatorja [online]. Master’s thesis. P. Pipp. [Accessed 11 April 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=102738
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Influence of velocity conditions at the entrance to the radial fan characteristics
Abstract:
In tumble dryers, we want to achieve high flows and pressures with the fan. High flows enable better blowing of the laundry and thus more efficient and shorter drying time. The influence of the entrances on the characteristic of the radial fan was determined at the measuring station where the performance and efficiency curves were measured and the velocity field at the inlet of the fan was determined with the hot wire anemometer. From the results, we found improvement in the performance and efficiency of the measured fan in the case of an inverted entrance according to its default position in the tumble dryer.

Keywords:tumble dryer, radial fan, measuring station, hot wire anemometry, fan characteristics, velocity field

Similar documents

Similar works from RUL:
  1. Development of simvastatin containing dried emulsions by using spray drying technology
  2. Preparation and characterization of carvedilol solid dispersions in mesoporous carrier silicon-dioxide using spray drying method
  3. Use of spray-drying method for the preparation of microcapsules with salicylic acid
  4. Preparation and characterization of carvedilol solid dispersion in mesoporus carriers using spray drying method
  5. A platform approach to protein encapsulates with controllable surface chemistry
Similar works from other Slovenian collections:
  1. ARTIFICIAL BEE COLONY ALGORITHM
  2. Possible textile industry wastewater treatment processes - European project ADOPBIO
  3. DEVELOPMENT OF THE TECHNOLOGICAL PROCESS OF OBTAINING FOOD CALCIUM PHOSPHATES
  4. Adaptive control based on computational intelligence
  5. Razpoznavanje delnih praznitev z nevronskim omrežjem

Back