izpis_h1_title_alt

Optimizacije delovanja biološkega dela Centralne čistilne naprave Nova Gorica : magistrsko delo
ID Lestan, Timotej (Author), ID Drev, Darko (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (5,90 MB)
MD5: 46ECDB6D78818475121BA5CA786ADD55
.pdfPDF - Appendix, Download (420,98 KB)
MD5: 7B6ED73646262D8118429C4724ADB7F7
.pdfPDF - Appendix, Download (172,17 KB)
MD5: AAA0EA3BE7AEE4BC462ADD5DBB6269C2
This document has even more files. Complete list of files is available below.

Abstract
Osrednja tema magistrske naloge je pregled in preračun možnosti optimizacije delovanja biološkega dela Centralne čistilne naprave Nova Gorica. V prvem delu naloge so predstavljena pomembnejša zakonodajna in teoretična izhodišča čiščenja odpadnih voda na čistilnih napravah. V drugem delu magistrska naloga predstavi rezultate eksperimentalnega dela, v sklopu katerih se je v laboratoriju analiziral odvzet vzorec odpadne vode iz čistilne naprave. Rezultate se je kasneje upoštevalo v eni izmed variant možnosti optimizacije delovanja čistilne naprave. Predstavljen je tudi uporabljen računalniški program, prav tako pa so podani vhodni podatki in predpostavke pri računskih postopkih. Za obravnavane obremenitvene variante ter dodatno varianto z upoštevanjem nadaljnje obdelave blata so se izračunali mogoči optimalni pogoji delovanja biološkega dela čistilne naprave pri danih vhodnih podatkih in predpostavkah. Ugotovilo se je, da pod določenimi pogoji biološki del čistilne naprave lahko deluje brez stroškov. Na koncu naloge je predstavljena primerjava rezultatov obravnavanih obremenitvenih variant.

Language:Slovenian
Keywords:biološko čiščenje, stroškovna učinkovitost, obdelava blata, Centralna čistilna naprava Nova Gorica
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Publisher:[T. Lestan]
Year:2018
PID:20.500.12556/RUL-101129 This link opens in a new window
UDC:628.32:58(497.4)(043.3)
COBISS.SI-ID:8416097 This link opens in a new window
Publication date in RUL:27.04.2018
Views:3105
Downloads:1054
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Optimisation of Operational Condition of Biological Treatment of Wastewater Plant Nova Gorica : master thesis
Abstract:
Thesis describes the review and optimization possibilities of wastewater treatment of central wastewater plant Nova Gorica. In the first part regulations and the theoretical background of biological wastewater treatment are presented. Which is followed by results of experiment done in laboratory. In the laboratory wastewater samples from abovementioned plant were analysed. The results were later used as input calculation data. The AquaDesigner software was used for calculation for the optimum operational conditions. Based on input data and prepositions calculation for all different variants including variant with additional waste sludge treatment were made. The conclusion was made that under given prepositions biological treatment of wastewater plant could operate at zero cost. At the end a comparison between the calculated variants were presented.

Keywords:biological wastewater treatment, cost efficiency, sewage sludge treatment, wastewater plant Nova Gorica