izpis_h1_title_alt

Frekvenčna regulacija radiofrekvenčne votline : diplomsko delo
ID Menart, Jure (Author), ID Kodek, Dušan (Mentor) More about this mentor... This link opens in a new window

URLURL - Presentation file, Visit http://eprints.fri.uni-lj.si/2577/ This link opens in a new window

Abstract
To diplomsko delo opisuje načrtovanje, razvoj in uporabo sistema za frekvenčno regulacijo EMMA pospeševalniške radiofrekvenčne votline. Problem pri radiofrekvenčnih votlinah je, da se zaradi različnih zunanjih dejavnikov (sprememba temperature okolice, mehanski stres, ...) neprestano frekvenčno premikajo (angl. detuning). Posledica frekvenčnega premika votline je, da elektromagnetno polje v votlini ni optimalno za pospešitev delcev. Zaradi tega morajo biti radiofrekvenčne votline krmiljene tako, da imajo resonančno frekvenco čim bližje predpisani. Ker so naštete spremembe relativno počasne, se lahko problem reši s počasno krmilno zanko. Za zajem radiofrekvenčnih signalov, njihovo analizo, samo krmilno zanko in pa izhod na koračne motorje sem uporabil napravo Libera LLRF podjetja Instrumentation Technologies d.d.

Language:Slovenian
Keywords:pospeševalniki delcev, krmilnik PID, računalništvo, univerzitetni študij, diplomske naloge
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FRI - Faculty of Computer and Information Science
Publisher:[J. Menart]
Year:2014
Number of pages:50 str.
PID:20.500.12556/RUL-68661 This link opens in a new window
UDC:004:621.3.038.62(043.2)
COBISS.SI-ID:10689364 This link opens in a new window
Publication date in RUL:10.07.2015
Views:1306
Downloads:183
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Frequency control of radiofrequency cavity
Abstract:
This work describes the design, development and application of the system for frequency control of EMMA accelerator radiofrequency cavity. The problem with the radiofrequency cavities is, that because of various factors (change in the environmental temperature, mechanical stress, ...), they are continuously frequency detuning. The consequence of the frequency detuning is that electromagnetic field in the cavity is not optimal for the acceleration of the particles. For this reason the resonant frequency of the cavities must be controlled so that it remains stable and as close to the nominal as possible. Because the above-mentioned factors are slow the problem can be solved with a slow control loop. For the acquisition of the radiofrequency signals, their analysis, control loop and the controlling of the stepper motors I have used instrument Libera LLRF from the company Instrumentation Technologies d.d.

Keywords:particle accelerators, PID controller, computer science, diploma

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back