izpis_h1_title_alt

The influence of airflow inlet region modifications on the local efficiency of natural draft cooling tower operation
Dvoršek, Matjaž (Avtor), Hočevar, Marko (Avtor), Širok, Brane (Avtor), Holeček, Nikola (Avtor), Donevski, Božin (Avtor)

URLURL - Predstavitvena datoteka, za dostop obiščite http://www.dlib.si/details/URN:NBN:SI:doc-QSEFUL21 Novo okno

Izvleček
We present the influence of the cooling tower airflow inlet region modifications at the Šoštanj 4 thermal power plant on cooling tower local efficiency. Local efficiency change was estimated based on temperature fields of drift eliminators before and after the reconstruction of the cooling tower. Temperature fields were measured with thermal vision method. The local reduction of cooling tower efficiency was analyzed based on phenomenological relations of heat transfer obtained from the selected vertical segment of the cooling tower. The characteristic influence that the reconstruction had on the temperature field was detected on the circumference of the cooling tower. The efficiency reduction was the highest on the periphery of the cooling tower and in particular section it peaked at 2%, while in most part of the areait was below 0.5%. The presented measurement and analysis method enables the estimation of changes in the local efficiency of heat transfer in cooling towers.

Jezik:Angleški jezik
Ključne besede:cooling tower, modifications, local efficiency, temperature
Vrsta gradiva:Delo ni kategorizirano (r6)
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Leto izida:2011
Založnik:= Association of Mechanical Engineers and Technicians of Slovenia et al.
Št. strani:str. 750-759
Številčenje:Vol. 57, no. 10
UDK:621.311.22
ISSN pri članku:0039-2480
DOI:10.5545/sv-jme.2010.208 Povezava se odpre v novem oknu
COBISS.SI-ID:12068891 Povezava se odpre v novem oknu
Število ogledov:429
Število prenosov:139
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
 
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
:
Objavi na: Bookmark and Share

Gradivo je del revije

Naslov:Strojniški vestnik
Skrajšan naslov:Stroj. vestn.
Založnik:Zveza strojnih inženirjev in tehnikov Slovenije [et al.], = Association of Mechanical Engineers and Technicians of Slovenia [et al.]
ISSN:0039-2480
COBISS.SI-ID:762116 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:hladilni stolp, modifikacija, lokalni izkoristek, temperatura, termalna kamera, meritve