Development and validation of an argon triple point apparatus with a novel automatic pressure control system
ID
Matas, Ivan
(
Author
),
ID
Grgec Bermanec, Lovorka
(
Author
),
ID
Šestan, Danijel
(
Author
),
ID
Bojkovski, Jovan
(
Author
),
ID
Žužek, Vincencij
(
Author
)
PDF - Presentation file,
Download
(13,90 MB)
MD5: BD27227CCA6E80DC749B3F1F5D24C599
URL - Source URL, Visit
https://www.mdpi.com/1424-8220/25/5/1411
Image galllery
Abstract
This paper describes the development and validation of an apparatus for the realization of the triple point of argon (83.8058 K), with a novel automatic pressure control system for the liquid nitrogen cryostat. The automatic pressure controller, together with custom-made software, was developed and tested in the Laboratory for Process Measurement at the Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb (FSB-LPM). Performance testing and characterization of the automatic pressure controller confirmed its suitability for precise and reliable control of gauge pressure in the cryostat. The characteristics and uncertainty of the measurement setup for the realization of the triple point of argon were validated through a bilateral hybrid comparison with the Laboratory of Metrology and Quality at the Faculty of Electrical Engineering, University of Ljubljana (MIRS/UL-FE/LMK). A long-stem quartz-sheathed standard platinum resistance thermometer was used as a transfer standard. The realizations of the International Temperature Scale (ITS-90) were compared in the subrange from the triple point of argon to the triple point of water. The comparison results show that resistance ratio (W) values determined by FSB-LPM at the fixed points of argon and mercury deviate from the MIRS/UL-FE/LMK values, within the determined combined uncertainty of the comparison.
Language:
English
Keywords:
triple point of argon
,
automatic pressure control
,
bilateral comparison
,
standard platinum resistance thermometer
,
International Temperature Scale of 1990
Work type:
Article
Typology:
1.01 - Original Scientific Article
Organization:
FE - Faculty of Electrical Engineering
Publication status:
Published
Publication version:
Version of Record
Year:
2025
Number of pages:
22 str.
Numbering:
Vol. 25, iss. 5, art. 1411
PID:
20.500.12556/RUL-167798
UDC:
621.317:006.91
ISSN on article:
1424-8220
DOI:
10.3390/s25051411
COBISS.SI-ID:
228749571
Publication date in RUL:
12.03.2025
Views:
99
Downloads:
26
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Copy citation
Share:
Record is a part of a journal
Title:
Sensors
Shortened title:
Sensors
Publisher:
MDPI
ISSN:
1424-8220
COBISS.SI-ID:
10176278
Licences
License:
CC BY 4.0, Creative Commons Attribution 4.0 International
Link:
http://creativecommons.org/licenses/by/4.0/
Description:
This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Secondary language
Language:
Slovenian
Keywords:
trojna točka argona
,
avtomatska regulacija tlaka
,
medlaboratorijska primerjava
,
standardni platinasti uporovni termometer
,
Mednarodna temperaturna lestvica iz 1990
Similar documents
Similar works from RUL:
Similar works from other Slovenian collections:
Back