<?xml version="1.0"?>
<metadata xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/"><dc:title>Development of flat panel detectors for time-of-flight positron emission tomography</dc:title><dc:creator>Orehar,	Matic	(Avtor)
	</dc:creator><dc:creator>Dolenec,	Rok	(Mentor)
	</dc:creator><dc:subject>Positron emission tomography</dc:subject><dc:subject>Time-of-flight</dc:subject><dc:subject>Monte Carlo simulations</dc:subject><dc:subject>Coincidence time resolution</dc:subject><dc:subject>Experimental measurements</dc:subject><dc:description>Positron emission tomography (PET) is an imaging modality in nuclear medicine primarily focused on imaging physiological processes within the body of a patient. One of the focuses in the development of PET detectors is the use of time-of-flight (TOF) information during image reconstruction. In order to achieve improvements in coincidence time resolution (CTR) every part of the detector requires improvement. As the CTR is improved, new possibilities emerge in the construction and use of PET scanners, such as open geometry and flat panel scanner configurations. The latter design could bring several advantages over the conventional cylindrical scanners, the principal being the reduction of the cost of the device. The new geometry also introduces several new challenges both in use and assessment of the scanner.

The optimisation of the novel scanner design was performed using Monte Carlo simulations, where various scanner configurations were compared to a reference scanner using various performance metrics for image quality with both standard and novel phantoms. As the novel geometry presented new challenges, such as the increased parallax error and reduced angular coverage, additional corrections were considered during image reconstruction alongside the study of various parameters used in the reconstruction process. Experimental measurements were performed using a pair of detector elements, with the aim of characterisation of the scintillators and photodetectors and evaluating the effects of the experimental parameters such as different bias voltages, optical coupling agents and acquisition hardware on the measured CTR.</dc:description><dc:date>2026</dc:date><dc:date>2026-10-02 08:15:26</dc:date><dc:type>Doktorsko delo/naloga</dc:type><dc:identifier>189150</dc:identifier><dc:identifier>VisID: 167817</dc:identifier><dc:identifier>COBISS_ID: 293663491</dc:identifier><dc:language>sl</dc:language></metadata>