<?xml version="1.0"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/"><rdf:Description rdf:about="https://repozitorij.uni-lj.si/IzpisGradiva.php?id=191316"><dc:title>Bubble-enhanced cold plasma improves microbial inactivation in water under scalable conditions</dc:title><dc:creator>Gonçalves,	José	(Avtor)
	</dc:creator><dc:creator>Pequeno,	João	(Avtor)
	</dc:creator><dc:creator>Žigon,	Jure	(Avtor)
	</dc:creator><dc:creator>Koritnik,	Tom	(Avtor)
	</dc:creator><dc:creator>Ferreira da Silva,	Filipe	(Avtor)
	</dc:creator><dc:creator>Kržišnik,	Davor	(Avtor)
	</dc:creator><dc:creator>Trkov,	Marija	(Avtor)
	</dc:creator><dc:creator>Diaz,	Israel	(Avtor)
	</dc:creator><dc:creator>Rodriguéz,	Elisa	(Avtor)
	</dc:creator><dc:creator>Dahle,	Sebastian	(Avtor)
	</dc:creator><dc:creator>Steyer,	Andrej	(Avtor)
	</dc:creator><dc:creator>Mauricio,	Rita	(Avtor)
	</dc:creator><dc:creator>Martinho,	Graça	(Avtor)
	</dc:creator><dc:subject>cold atmospheric plasma</dc:subject><dc:subject>environmental biotechnology</dc:subject><dc:subject>water disinfection</dc:subject><dc:subject>bioprocess engineering</dc:subject><dc:subject>Escherichia coli</dc:subject><dc:subject>Bacillus subtilis</dc:subject><dc:description>Cold atmospheric plasma (CAP) is emerging as an environmentally friendly disinfection technology, but most plasma-liquid systems remain confined to millilitre‑scale volumes, limiting their applicability as bioprocesses for water treatment. Here, we designed and evaluated a bubble‑enhanced dielectric barrier discharge reactor, the Spiral Plasma Aeration Reactor Column (SPARC), as an environmental technology approach for litre‑scale inactivation of model bacteria in water. Direct CAP exposure achieved rapid, near‑complete inactivation of Escherichia coli and Bacillus subtilis in 200 µL, but performance decreased sharply at 100 mL, confirming strong volume dependence under surface‑limited plasma-liquid contact. Coupling CAP with gas bubbling (2 L·min−1) in SPARC markedly enhanced inactivation at 250–500 mL, achieving approximately 2–3 log reductions (≥ 99–99.9%) for E. coli and B. subtilis within 60 min, whereas non-aerated CAP remained below ≈0.8-log (≤ 60%) reduction under identical conditions. At 1 L under high initial loads (~ 106–107 CFU·100 mL−1), bubble-assisted CAP yielded ~ 4-log inactivation of E. coli and 3–3.5-log reduction of B. subtilis, including continued post-treatment inactivation consistent with plasma-activated water effects. In a protein‑rich organic matrix, early‑stage inactivation was attenuated, but SPARC still achieved ≈2–3‑log reductions, indicating robust yet matrix‑sensitive performance under wastewater‑like conditions. At fixed electrical input (34.5 W), specific energy consumption ranged from 60 kWh·m−3 (250 mL, 30 min, &gt; 99% E. coli inactivation) to 30 kWh·m−3 (1 L, 60 min, ≈4‑log E. coli inactivation), corresponding to ≈7.5 kWh·log₁₀−1·m−3. These results position bubble‑assisted CAP as a promising environmental biotechnology and bioprocess platform for water disinfection and emphasise the central role of reactor and contactor design in determining microbial efficacy and energy demand.</dc:description><dc:date>2026</dc:date><dc:date>2026-11-16 12:37:09</dc:date><dc:type>Članek v reviji</dc:type><dc:identifier>191316</dc:identifier><dc:language>sl</dc:language></rdf:Description></rdf:RDF>
