<?xml version="1.0"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/"><rdf:Description rdf:about="https://repozitorij.uni-lj.si/IzpisGradiva.php?id=154018"><dc:title>A simplified nasopharyngeal swab collection procedure for minimizing patient discomfort while retaining sample quality</dc:title><dc:creator>Uršič,	Tina	(Avtor)
	</dc:creator><dc:creator>Kogoj,	Rok	(Avtor)
	</dc:creator><dc:creator>Šikonja,	Jaka	(Avtor)
	</dc:creator><dc:creator>Jevšnik Virant,	Monika	(Avtor)
	</dc:creator><dc:creator>Petrovec,	Miroslav	(Avtor)
	</dc:creator><dc:subject>nasopharyngeal swab</dc:subject><dc:subject>collection procedure</dc:subject><dc:subject>sample quality</dc:subject><dc:subject>discomfort score</dc:subject><dc:subject>Ubiquitin C</dc:subject><dc:description>A nasopharyngeal swab (NPS) is the most frequently collected sample type when molecular diagnosis of respiratory viruses, including SARS CoV-2, is required. An optimal collection technique would provide sufficient sample quality for the diagnostic process and would minimize the discomfort felt by the patient. This study compares a simplified NPS collection procedure with only one rotation of the swab to a more standard procedure with five rotations. Swabs were collected from 76 healthy volunteers by the same healthcare professional on 2 consecutive days at a similar hour to minimize variability. The number of Ubiquitin C copy number per sample was measured by real-time quantitative PCR and patient discomfort was assessed by questionnaire. No statistically significant difference (p = 0.15) was observed in the Ubiquitin C copy number per sample between a NPS collected with one rotation (5.2 ± 0.6 log UBC number copies/sample) or five rotations (5.3 ± 0.5 log UBC number copies/sample). However, a statistically significant difference was observed in discomfort between these two procedures, the second being much more uncomfortable. Additional analysis of the results showed a weak correlation between discomfort and the number of human cells recovered (Spearman's rho = 0.202) and greater discomfort in younger people. The results of this study show that a NPS collected with one slow rotation has the same quality as a NPS collected with five rotations. However, the collection time is shorter and, most importantly, less unpleasant for patients.</dc:description><dc:date>2023</dc:date><dc:date>2024-01-19 12:13:52</dc:date><dc:type>Članek v reviji</dc:type><dc:identifier>154018</dc:identifier><dc:language>sl</dc:language></rdf:Description></rdf:RDF>
