Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Metric characteristics of various methods for numerical density estimation in transmission light microscopy - a computer simulation
ID
Kališnik, Miroslav
(
Avtor
),
ID
Blejec, Andrej
(
Avtor
),
ID
Pajer, Zdenka
(
Avtor
),
ID
Majhenc, Janja
(
Avtor
)
URL - Predstavitvena datoteka, za dostop obiščite
http://www.dlib.si/details/URN:NBN:SI:doc-G28BTM1E
Galerija slik
Izvleček
In the introduction the evolution of methods for numerical density estimation of particles is presented shortly. Three pairs of methods have been analysed and compared: (1) classical methods for particles counting in thin and thick sections, (2) original and modified differential counting methods and (3) physical and optical disector methods. Metric characteristics sush as accuracy, efficiency, robustness, and feasibility of methods have been estimated and compared. Logical, geometrical and mathematical analysis as well as computer simulations have been applied. In computer simulations a model of randomly distributed equal spheres with maximal contrast against sorrundings has been used. According to our computer simulation all methods give accurate results provided that the sample is representative and sufficiently large. However, there are differences in their efficiency, robustness and feasibility. Efficiency and robustness increase with increasing slice thickness in all three pairs of methods. Robustness is superior in both differential and both disector methods compared to both classical methods. Feasibility can be judged according to the additional equipment as well as to the histotechnical and counting procedures necessary for performing individual counting methods. However, it is evident that not all practical problems can efficiently be solved with models.
Jezik:
Angleški jezik
Ključne besede:
accuracy
,
efficiency
,
feasibility
,
light microscopy
,
numerical density
,
robustness
,
vertical resolution
Vrsta gradiva:
Delo ni kategorizirano
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
BF - Biotehniška fakulteta
Založnik:
Društvo za stereologijo in kvantitativno analizo slike, Medicinska fakulteta
Leto izida:
2001
Št. strani:
Str. 15-25
Številčenje:
Vol. 20, no. 1
PID:
20.500.12556/RUL-63827
UDK:
621.38
ISSN pri članku:
1580-3139
COBISS.SI-ID:
836943
Datum objave v RUL:
10.07.2015
Število ogledov:
1422
Število prenosov:
652
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Image analysis & stereology
Skrajšan naslov:
Image anal. stereol.
Založnik:
Društvo za stereologijo in kvantitativno analizo slike, Medicinska fakulteta
ISSN:
1580-3139
COBISS.SI-ID:
106479104
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj