izpis_h1_title_alt

Vpliv EAF C žlindre na fizikalno-mehanske lastnosti betona : diplomska naloga
ID Štokelj, Matevž (Avtor), ID Bokan-Bosiljkov, Violeta (Mentor) Več o mentorju... Povezava se odpre v novem oknu, ID Cotič, Zvonko (Komentor)

.pdfPDF - Predstavitvena datoteka, prenos (1,53 MB)
MD5: B1F85772F35739308B18B1AA5FC5C2DE
PID: 20.500.12556/rul/0cd958e1-1cfb-438d-b5e2-a6c4c875c55b

Izvleček
V diplomski nalogi sem ugotavljal, kakšen vpliv ima EAF C žlindra na fizikalno-mehanske lastnosti betona. V ta namen sem izdelal dve betonski mešanici po enaki recepturi, pri čemer sem uporabil različna agregata. V prvi mešanici sem uporabil žlindrin, v drugi pa drobljen apnenčev agregat. Najprej sem preizkušal lastnosti betona v svežem stanju, kjer sem meril konsistenco betona po metodi poseda stožca, delež por v betonu s pomočjo poroziometra ter temperaturo betona. Na strjenem betonu sem ugotavljal tlačno in upogibno natezno trdnost vzorcev ter njihovo odpornost proti prodoru vode pod pritiskom. Zanimalo me je, ali lahko z obema mešanicama dosežemo enake oziroma primerljive vrednosti, torej ali z uporabo žlindrinega agregata vplivamo na karakteristike betona.

Jezik:Slovenski jezik
Ključne besede:gradbeništvo, diplomska naloga, UNI, B-GR, žlindra, odpornost betona, vodotesnost betona
Vrsta gradiva:Diplomsko delo/naloga
Tipologija:2.11 - Diplomsko delo
Organizacija:FGG - Fakulteta za gradbeništvo in geodezijo
Kraj izida:Ljubljana
Založnik:[M. Štokelj]
Leto izida:2014
Št. strani:VIII, 23 str.
PID:20.500.12556/RUL-32455 Povezava se odpre v novem oknu
UDK:691.322(043.2)
COBISS.SI-ID:6820449 Povezava se odpre v novem oknu
Datum objave v RUL:10.07.2015
Število ogledov:4071
Število prenosov:460
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:EAF C Slag influence on physical and mechanical properties of concrete
Izvleček:
The diploma thesis deals with the influence of the EAF slag C on physical-mechanical properties of concrete. Two concrete mixtures were designed according to the same recipe; however, two different aggregates with the same volume fraction were used. In the first mix the slag was applied and in the second one crushed limestone aggregate was incorporated. First the properties of concrete in the fresh state were tested: consistency of concrete by the slump method, content of air pores using pressure gauge method and measurements of temperature. In the hardened state of concrete compressive and flexural tensile strength of samples were tested and resistance of concrete to penetration of water under pressure was determined. The aim of the thesis was to establish whether both concrete mixtures have comparable properties and if and how we influence the concrete properties when using the slag aggregate.

Ključne besede:slag, concrete resistance, water penetration