Experimental characterization of sliding and shear mechanisms in EPS-insulated foundations for seismic loading conditions
ID
Snoj, Jure
(
Avtor
),
ID
Dolšek, Matjaž
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(11,62 MB)
MD5: FEC218F23C3B6E4FD6ABB300A6F52EAE
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S014102962601312
Galerija slik
Izvleček
Thermally insulated foundation systems with expanded polystyrene (EPS) layers placed beneath reinforced concrete slabs are increasingly used in practice. However, their mechanical behavior under combined normal and cyclic shear loading is not sufficiently documented for structural and seismic analyses. This study presents an experimental investigation of the frictional, shear, and compressive response of EPS-insulated foundation assemblies. Monotonic and cyclic shear tests were performed on single-layer and double-layer EPS configurations, including button–groove connections. The specimens were placed over a waterproofing membrane either freely or bonded with adhesive. The results showed that sliding at the EPS–waterproofing interface governs the response of the assembly. The shear capacity of button–groove connections (approximately 80–100 kPa) and of homogeneous EPS layers (approximately 170 kPa) exceeded the shear stress at sliding initiation. This indicates that failure within EPS material or at the interlayer connection is not expected prior to interface sliding. Static and kinetic friction coefficients were determined as 0.61 and 0.58 for freely placed insulation, and 0.96 and 0.65 for bonded insulation. Limited cyclic tests provided qualitative information on the hysteretic response of the interface. The results suggest that the envelope response may be approximated by a simple elasto-plastic relationship. Compressive tests confirmed that EPS400 panels reached strengths between 440 and 487 kPa at 10% strain and exhibiting progressive densification without brittle failure.
Jezik:
Angleški jezik
Ključne besede:
base-insulated buildings
,
cyclic test
,
expanded polystyrene
,
shear resistance
,
compressive resistance
,
seismic performance assessment
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
FGG - Fakulteta za gradbeništvo in geodezijo
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2026
Št. strani:
15 str.
Številčenje:
Vol. 366, Part B, art. 123398
PID:
20.500.12556/RUL-185230
UDK:
699.8
ISSN pri članku:
1873-7323
DOI:
10.1016/j.engstruct.2026.123398
COBISS.SI-ID:
286351875
Datum objave v RUL:
29.07.2026
Število ogledov:
38
Število prenosov:
21
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Engineering structures
Založnik:
Elsevier
ISSN:
1873-7323
COBISS.SI-ID:
23165701
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
ocena potresne zmogljivosti
,
toplotna izolacija pod temelji
,
ciklični test
,
ekspandirani polistiren
,
strižna nosilnost
,
tlačna nosilnost
Projekti
Financer:
ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:
P2-0185
Naslov:
Potresno inženirstvo
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj