Realizing the redefined Kelvin : extending the life of ITS-90
ID Pearce, J. V. (Avtor), ID Rusby, Richard (Avtor), ID Veltcheva, R. I. (Avtor), ID Campo, Dolores del (Avtor), ID Garcia-Izquierdo, C. (Avtor), ID Merlone, Andrea (Avtor), ID Coppa, Graziano (Avtor), ID Kowal, A. (Avtor), ID Eusebio, L. (Avtor), ID Bojkovski, Jovan (Avtor), ID Žužek, Vincencij (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,40 MB)
MD5: 02ED8737B1C0A1D6001F5B8D088C8600
URLURL - Izvorni URL, za dostop obiščite https://pubs.aip.org/aip/acp/article/3230/1/020002/3317414/Realizing-the-redefined-Kelvin-Extending-the-life Povezava se odpre v novem oknu

Izvleček
Following the redefinition of the kelvin, the user is presented with a more nuanced traceability route for temperature through the mise en pratique for the definition of the kelvin (MeP-K-19). Here we describe research to address several present and potential shortcomings with the current main dissemination route, namely the International Temperature Scale of 1990 (ITS-90). The ITS-90 has served the global temperature measurement community well, providing reliable, low uncertainty traceability for over 30 years. However, there are some potentially life-limiting issues for it. Among these are the impact of the main types (1 and 3) of non-uniqueness which represent an important contribution to the uncertainties achievable with the ITS-90, and the possible need to identify an alternative to the mercury triple point, a key fixed point of the ITS-90 whose use could be banned by an international treaty. Significant progress has been made in addressing these problems through a) new determinations of Type 3 non-uniqueness which have been undertaken in the range –189 °C to 156 °C; b) a comprehensive evaluation of Type 1 non-uniqueness on a large number of Standard Platinum Resistance Thermometers (SPRTs) across multiple temperature regions; c) comparison of high temperature SPRTs in pressure-controlled heat pipes to characterize Type 3 non-uniqueness between 660.323 °C and 961.78 °C and d) new designs of ▫$CO_2$▫ and ▫$SF_6$▫ cells for use with long-stem SPRTs. The fixed-point cells have been improved compared to previous versions by using purer gases and more stable and uniform temperature-controlled baths, and by the development of a flexible set-up that can accommodate both capsule and long-stem SPRTs. The effect of replacing mercury on the ITS-90 interpolating equations and uncertainty propagation has also been investigated.

Jezik:Angleški jezik
Ključne besede:kelvin, International Temperature Scale of 1990, standard platinum resistance thermometer, scale non-uniqueness, new temperature fixed-points
Vrsta gradiva:Članek v reviji
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:020002-1-020002-9
Številčenje:Vol. 3230, iss. 1, art. 020002
PID:20.500.12556/RUL-167928 Povezava se odpre v novem oknu
UDK:621.317:006.91
ISSN pri članku:1551-7616
DOI:10.1063/5.0234458 Povezava se odpre v novem oknu
COBISS.SI-ID:229648131 Povezava se odpre v novem oknu
Datum objave v RUL:20.03.2025
Število ogledov:382
Število prenosov:117
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:AIP conference proceedings
Skrajšan naslov:AIP conf. proc.
Založnik:American Institute of Physics
ISSN:1551-7616
COBISS.SI-ID:519457817 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:kelvin, Mednarodna temperaturna lestvica iz 1990, standardni platinasti uporovni termometer, neenakost lestvice, nove temperaturne fiksne točke

Projekti

Financer:Drugi - Drug financer ali več financerjev
Program financ.:European Metrology Programme for Innovation and Research
Številka projekta:18SIB02
Naslov:Realising the redefined kelvin
Akronim:Real-K

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj