izpis_h1_title_alt

Longitudinal strain vs. conventional echocardiographic parameters in the first week of life in healthy term newborns
ID Peček, Jerneja (Avtor), ID Koželj, Mirta (Avtor), ID Fister, Petja (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (612,89 KB)
MD5: 0734251055E08941A085BB49AAD97B56
URLURL - Izvorni URL, za dostop obiščite https://link.springer.com/article/10.1007/s00246-023-03291-x Povezava se odpre v novem oknu

Izvleček
The first week of life is characterized by substantial alterations in hemodynamic conditions. Changes in myocardial contractility will reflect these changes. We aimed to assess right and left ventricular function on the third and seventh days of life in 50 healthy term newborns. To assess myocardial function, we used speckle tracking echocardiography. Pulsed-wave tissue Doppler imaging, M-mode, Doppler and pulsed-wave Doppler were also used to assess ventricular function. We found a significant increase in both right and left longitudinal strain and an increase in systolic and diastolic tissue Doppler velocities, whereas most other parameters remained unchanged. At both time points, the measured parameters were significantly greater for the right ventricle, but the changes with time were similar for both ventricles. We also found an increase in right ventricular outflow tract acceleration time as an indirect sign of decreasing pulmonary vascular resistance and an increase in systolic blood pressure, pointing to increasing systemic vascular resistance. Together with a decreasing proportion of patients with patent ductus arteriosus, the estimated left ventricular cardiac output decreased and right ventricular cardiac output increased but not to a statistically significant degree. In conclusion, the results of our study show how different echocardiographic techniques capture hemodynamic changes and changes in myocardial contractility and compliance. Both longitudinal strain and tissue Doppler imaging parameters seem to offer greater sensitivity in comparison with conventional echocardiographic parameters.

Jezik:Angleški jezik
Ključne besede:echocardiography, longitudinal strain, newborn, speckle tracking
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:Str. 32–39
Številčenje:Vol. 45, iss. 1
PID:20.500.12556/RUL-154830 Povezava se odpre v novem oknu
UDK:61
ISSN pri članku:1432-1971
DOI:10.1007/s00246-023-03291-x Povezava se odpre v novem oknu
COBISS.SI-ID:186812419 Povezava se odpre v novem oknu
Datum objave v RUL:05.03.2024
Število ogledov:400
Število prenosov:30
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Pediatric cardiology
Skrajšan naslov:Pediatr. cardiol.
Založnik:Springer Nature
ISSN:1432-1971
COBISS.SI-ID:512031257 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj