izpis_h1_title_alt

Study of different types of copper electrodes for anodic stripping voltammetric detection of trace metal ions
ID Obrez, Domen (Avtor), ID Kolar, Mitja (Avtor), ID Tasić, Nikola (Avtor), ID Hočevar, Samo B. (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (11,46 MB)
MD5: 90C83492BA7B3B3EF7F369C3ED9CA1C4
URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S0013468623006588 Povezava se odpre v novem oknu

Izvleček
Copper electrodes exhibit interesting characteristics for application in electrochemical stripping analysis and represent another alternative to their mercury counterparts. In this work, we studied different types of copper-based electrodes for anodic stripping voltammetric detection of trace metal ions. We investigated copper film (CuFE), and bulk copper electrodes, such as in-situ and ex-situ prepared CuFEs using glassy carbon and screen-printed carbon supporting electrodes, a bulk copper disk and screen-printed copper electrode, and a copper wire as the simplest, inexpensive, and readily available analog. For studying their electroanalytical performances, low concentrations (μg L$^{−1}$) of Cd(II) and Pb(II) were used as model ions. We examined and optimized several key parameters affecting the preparation and functioning of copper electrodes, such as the composition of the measurement solution, copper concentration for in-situ and ex-situ preparation of CuFE, deposition potential, deposition time, etc. Most of the tested copper electrodes showed favorable stripping voltammetric performances, particularly the CuFE ex-situ prepared on a glassy carbon electrode and the CuFE in-situ prepared on a screen-printed carbon substrate. Notably, a copper wire revealed an excellent electroanalytical operation with a limit of detection of 0.6 μg L$^{−1}$ for Pb(II) and 1.8 μg L$^{−1}$ for Cd(II). The practical applicability of a copper electrode was tested by measuring a real tap water sample.

Jezik:Angleški jezik
Ključne besede:copper film electrode, copper bulk electrode, copper wire electrode, lead, cadmium, anodic stripping voltammetry
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FKKT - Fakulteta za kemijo in kemijsko tehnologijo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:11 str.
Številčenje:Vol. 457, art. 142480
PID:20.500.12556/RUL-148304-0bdf530a-5381-69c9-8e04-e03bd8d541a5 Povezava se odpre v novem oknu
UDK:543.552
ISSN pri članku:1873-3859
DOI:10.1016/j.electacta.2023.142480 Povezava se odpre v novem oknu
COBISS.SI-ID:151348483 Povezava se odpre v novem oknu
Datum objave v RUL:11.08.2023
Število ogledov:818
Število prenosov:58
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Electrochimica acta
Založnik:Elsevier, International Society of Electrochemistry
ISSN:1873-3859
COBISS.SI-ID:135479555 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:bakrove elektrode, priprava elektrodnih površin, določanje svinca, določanje kadmija, anodna striping voltametrija

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0034
Naslov:Analitika in kemijska karakterizacija materialov ter procesov

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0153
Naslov:Raziskave in razvoj analiznih metod in postopkov

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj