Erect pelvic radiography with fat tissue displacement : impact on radiation dose and image quality
ID
Trožić, Šejla
(
Avtor
),
ID
England, Andrew
(
Avtor
),
ID
Mekiš, Nejc
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(631,24 KB)
MD5: 557D9DB7BD7D4806E547F32F6364BB3B
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S1078817423000718
Galerija slik
Izvleček
Introduction: Pelvic radiography is one of the most frequent general radiography imaging procedures. Pelvic radiography is usually performed in the supine position, but in some cases erect imaging is performed. The aim of this study was to determine whether radiation dose and image quality differ between two different erect pelvic radiographic procedures in overweight and obese patients, with and without displacement of anterior adipose tissue. Methods: This research was a two-part study. The first part of the study was to determine a suitable fat displacement band that would not produce artifacts on the resulting radiograph when fat tissue was displaced. The second part of the study was performed in a clinical setting on 60 overweight or obese patients (BMI ≥25) referred for erect pelvic imaging. Patients were randomly divided into two equal groups, half of which displaced adipose tissue from the region of interest and the other group did not. Waist and hip circumference, height, weight, dose-area- product (DAP), primary field size, source-to-skin distance, mAs, and kV were measured. Body Mass Index (BMI), entrance surface dose (ESD), and effective dose (ED) were then calculated. The resulting images were evaluated by three radiologists. Results: It was found that a thin cotton triangular bandage produced no visible radiographic artefacts. In the group of patients using the fat displacement protocol, a statistically significant reduction in waist circumference (4.7%), DAP (38.5%), ESD (44%) and ED (38.7%) were observed (p < 0.05). In addition, a significant (p < 0.05) increase was found for all the observed image quality criteria and overall total image score with exception of sacroiliac joint, iliac crest and pubic/ischial rami. Conclusion: Based on the results, the use of the adipose tissue displacement protocol for radiography of the pelvis and hip in the erect position in overweight and obese patients is recommended. Implications for practice: The use of cotton bands to remove adipose tissue during pelvic imaging in obese and overweight patients results in a reduction of radiation dose received by the patient and improves image quality. This technique is quick, easy, and inexpensive.
Jezik:
Angleški jezik
Ključne besede:
erect pelvic radiography
,
fat tissue displacement
,
image quality
,
radiation dose
,
radiography
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
ZF - Zdravstvena fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2023
Št. strani:
Str. 546-551
Številčenje:
Vol. 29, iss. 3
PID:
20.500.12556/RUL-145052
UDK:
616-073
ISSN pri članku:
1078-8174
DOI:
10.1016/j.radi.2023.03.004
COBISS.SI-ID:
147388419
Datum objave v RUL:
31.03.2023
Število ogledov:
819
Število prenosov:
107
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Radiography
Skrajšan naslov:
Radiography
Založnik:
Elsevier, The College of Radiographers
ISSN:
1078-8174
COBISS.SI-ID:
383851
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
radiografija pokončne medenice
,
premik maščobnega tkiva
,
kakovost slike
,
doza sevanja
,
radiografija