izpis_h1_title_alt

Comparison between the Sofia SARS antigen FIA test and the PCR test in detection of SARS-CoV-2 infection
ID Černila, Manca (Avtor), ID Logar, Mateja (Avtor), ID Možina, Hugon (Avtor), ID Osredkar, Joško (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (200,79 KB)
MD5: 6776D5CEC33D4186BE21D2F8772D4450
URLURL - Izvorni URL, za dostop obiščite https://academic.oup.com/labmed/article/54/2/e44/6670753 Povezava se odpre v novem oknu

Izvleček
Objective: The purpose of this study was to compare Quidel’s rapid antigen test Sofia SARS antigen Fluorescent Immunoassay (FIA) (Sofia) with the real-time reverse transcription–polymerase chain reaction (rRT-PCR) test. Methods: Two samples were taken from each test subject—1 for testing with the Sofia test and 1 for testing with the rRT-PCR test. In total, swabs were taken from 146 subjects who presented symptoms of infection (group 1) and 672 subjects who were tested regardless of symptoms (group 2). Results: In group 1, the sensitivity of the antigen test was 90.0% and its specificity 97.5%. In group 2, however, the sensitivity of the antigen test was 81.4% and the specificity 98.9%. In addition to asymptomatic patients, false-negative results of rapid antigen tests also occurred in subjects with high threshold values (cycle threshold > 30). Conclusion: Our results show that the Sofia test meets the standards for diagnostic tests according to the criteria of the World Health Organization, as they show high sensitivity and specificity, and perhaps most importantly, a high negative predictive value (> 95%).

Jezik:Angleški jezik
Ključne besede:COVID-19, SARS-CoV-2, Sofia SARS antigen FIA, clinical validity, analytical validity, rapid antigen testing
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FFA - Fakulteta za farmacijo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:Str. e44–e48
Številčenje:Vol. 54, iss. 2
PID:20.500.12556/RUL-144980 Povezava se odpre v novem oknu
UDK:616-07:616.98-036.21:578.834
ISSN pri članku:1943-7730
DOI:10.1093/labmed/lmac079 Povezava se odpre v novem oknu
COBISS.SI-ID:118589187 Povezava se odpre v novem oknu
Datum objave v RUL:28.03.2023
Število ogledov:568
Število prenosov:80
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Laboratory medicine
Skrajšan naslov:Lab. med.
Založnik:Oxford University Press, American Society for Clinical Pathology
ISSN:1943-7730
COBISS.SI-ID:525526553 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:Sofia SARS antigen FIA, klinična veljavnost, analitična veljavnost, hitro testiranje na antigen, COVID-19, SARS-CoV-2, diagnostika

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj