izpis_h1_title_alt

Study on occupants' window view quality vote and their physiological response
ID Domjan, Suzana (Avtor), ID Arkar, Ciril (Avtor), ID Medved, Sašo (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (14,74 MB)
MD5: 43D1A44632A8E03C0BABFEF1C30DD8C3
URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S235271022300298X Povezava se odpre v novem oknu

Izvleček
The window view quality related to the window view motif was recently introduced in buildings' certification methods such as LEED, BREAM, WELL and in technical standard EN 17037 as well. The experimental study of psychological and physiological response of observers to window view was performed in thermostatic chamber at class I of indoor environment quality conditions. The aim of the study was to: i) review models for numerical characterization of window view motifs; ii) collect observers' votes of window view quality, using 5-point Likert scale, with experiment simulating different window view motifs; iii) propose a new model for predicting window view quality vote, based on characterization of a window view motif, with additional consideration of sunny or cloudy conditions; iv) measure the brain waves power during window view observation in resting state, using wearable electroencephalography device, to find out to what extend observers' votes correlates with their physiological response. The results show that window view votes increase in case of dominance of natural elements, however the window view votes of built environment significantly increase in case of sunny conditions as well. No significant difference in window view votes was found regarding to the gender or age of observers. It was found that ranking, used in reviewed methods, significantly differ in correlation to our experimental results, with Spearman's correlation index from -0.35 (EN 17037) to 0.85 (View-out Quality Index method). The best fit model was upgraded with additional parameter, indicating sunny or cloudy conditions, defined as Window View Index. The power of alpha waves, the frontal alpha asymmetry and the alpha to beta ratio were used as physiological response indicators, because they are related to the observes' resting state. It was found out that physiological response is significantly less pronounced as observers' votes. Among analyzed biomarkers frontal alpha asymmetry shows the highest positive response, regardless of gender, to window views with dominated natural elements and also to sunny conditions. Based on these results we recommend frontal alpha asymmetry as most suitable biomarker in research of window view impact on well-being of occupants.

Jezik:Angleški jezik
Ključne besede:buildings' sustainability certification, occupants' evaluation, window view assessment method, wearable electroencephalography devices
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:17 str.
Številčenje:Vol. 68, art. 106119
PID:20.500.12556/RUL-144587 Povezava se odpre v novem oknu
UDK:502.131.1
ISSN pri članku:2352-7102
DOI:10.1016/j.jobe.2023.106119 Povezava se odpre v novem oknu
COBISS.SI-ID:143801347 Povezava se odpre v novem oknu
Datum objave v RUL:02.03.2023
Število ogledov:778
Število prenosov:120
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Journal of building engineering
Založnik:Elsevier
ISSN:2352-7102
COBISS.SI-ID:525380633 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:trajnostno certificiranje stavb, osebne ocene uporabnikov, metode ocenjevanja okoljskih scen, nosljive EEG naprave

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:L2-3172
Naslov:Razvoj tehničnih smernic za štirislojne zasteklitve

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj