Size- and time-dependent aerosol removal from a protective box during simulated intubation and extubation procedures
ID Pirker, Luka (Avtor), ID Čebašek, Metod (Avtor), ID Serdinšek, Matej (Avtor), ID Remškar, Maja (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (20,98 MB)
MD5: ADB8D0782BA5B44877806B72A3FB01F2
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2673-8112/1/1/25 Povezava se odpre v novem oknu

Izvleček
Because the SARS-CoV-2 virus primarily spreads through droplets and aerosols, a protective box could provide adequate protection by shielding medical professionals during the intubation and extubation procedures from generated droplets and aerosols. In this study, size- and timedependent aerosol concentrations were measured inside and outside the protective box in the particle size ranging from 14 nm to 20 µm during simulated intubation and extubation procedures. An improved protective box with active ventilation was designed based on a plastic bag with armholes covered with latex sheets that utilizes a supportive frame. Coughing during the intubation and extubation procedure was simulated using an aerosol generator which dispersed the aerosol powder into the protective box. During the intubation and extubation procedure, the concentration of particles increased inside the protective box but, due to the high negative airflow, quickly dropped to background levels. The particle concentration of all measured particle sizes decreased within the same time frame. No leakage of particles was observed through the armhole openings. The presented protective box design provides excellent protection against generated droplets and aerosols. The decrease in concentration does not depend on the particle size. Outside the box, particle concentration did not change with time.

Jezik:Angleški jezik
Ključne besede:aerosol-generating procedure, COVID-19, extubation, intubation, protective box
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FMF - Fakulteta za matematiko in fiziko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2021
Št. strani:Str. 315-324
Številčenje:Vol. 1, iss. 1
PID:20.500.12556/RUL-136172 Povezava se odpre v novem oknu
UDK:61
ISSN pri članku:2673-8112
DOI:10.3390/covid1010025 Povezava se odpre v novem oknu
COBISS.SI-ID:93028355 Povezava se odpre v novem oknu
Datum objave v RUL:14.04.2022
Število ogledov:842
Število prenosov:182
Metapodatki:XML DC-XML DC-RDF
:
PIRKER, Luka, ČEBAŠEK, Metod, SERDINŠEK, Matej in REMŠKAR, Maja, 2021, Size- and time-dependent aerosol removal from a protective box during simulated intubation and extubation procedures. COVID [na spletu]. 2021. Vol. 1, no. 1, p. 315–324. [Dostopano 4 maj 2025]. DOI 10.3390/covid1010025. Pridobljeno s: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=slv&id=136172
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:COVID
Založnik:MDPI AG
ISSN:2673-8112
COBISS.SI-ID:78587651 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:01.09.2021

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0099
Naslov:Fizika mehkih snovi, površin in nanostruktur

Podobna dela

Podobna dela v RUL:
  1. Izdelava merilnika sile, izvedba meritev in MKE simulacije mehkega robotskega prijemala
  2. Merilnik navora in moči kolesarja
  3. Merjenje notranje osne sile v nosilcu z uporabo merilnih lističev
  4. Izdelava merilnega sistema za merjenje sile z uporabo merilnih lističev in mikrokrmilnika Arduino
  5. Vključitev funkcionalnosti uporovnega merilnega lističa v strukturo 3D tiskanega izdelka
Podobna dela v drugih slovenskih zbirkah:
  1. Obdelava signala sile dušenja blažilnika
  2. Vertical displacements measuring methods during bridge load tests
  3. Processing of signals produced by strain gauges in testing measurements of the bridges
  4. The different methods of displacement monitoring at loading tests of bridges or different structures
  5. Rotacijski merilnik momenta

Nazaj