Effect of the dynamic response of a side-wall pressure measurement system on determining the pressure step signal in a shock tube using a time-of-flight method
ID Svete, Andrej (Avtor), ID Hernández Castro, Francisco Javier (Avtor), ID Kutin, Jože (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,16 MB)
MD5: 8FFE9D5887FC8C0DA5B9497FEBC5D43C
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/1424-8220/22/6/2103 Povezava se odpre v novem oknu

Izvleček
Technological progress demands accurate measurements of rapidly changing pressures. This, in turn, requires the use of dynamically calibrated pressure meters. The shock tube enables the dynamic characterization by applying an almost ideal pressure step change to the pressure sensor under calibration. This paper evaluates the effect of the dynamic response of a side-wall pressure measurement system on the detection of shock wave passage times over the side-wall pressure sensors installed along the shock tube. Furthermore, it evaluates this effect on the reference pressure step signal determined at the end-wall of the driven section using a time-of-flight method. To determine the errors in the detection of the shock front passage times over the centers of the side-wall sensors, a physical model for simulating the dynamic response of the complete measurement chain to the passage of the shock wave was developed. Due to the fact that the use of the physical model requires information about the effective diameter of the pressure sensor, special attention was paid to determining the effective diameter of the side-wall pressure sensors installed along the shock tube. The results show that the relative systematic errors in the pressure step amplitude at the end-wall of the shock tube due to the errors in the detection of the shock front passage times over the side-wall pressure sensors are less than 0.0003%. On the other hand, the systematic errors in the phase lag of the end-wall pressure signal in the calibration frequency range appropriate for high-frequency dynamic pressure applications are up to a few tens of degrees. Since the target phase measurement uncertainty of the pressure sensors used in high-frequency dynamic pressure applications is only a few degrees, the corrections for the systematic errors in the detection of the shock front passage times over the side-wall pressure sensors with the use of the developed physical dynamic model are, therefore, necessary when performing dynamic calibrations of pressure sensors with a shock tube.

Jezik:Angleški jezik
Ključne besede:time-varying pressure, primary calibration method, diaphragmless shock tubes, time-of-flight method, shock wave velocity, piezoelectric pressure measurement systems, uncertainty analysis
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2022
Št. strani:15 str.
Številčenje:Vol. 22, iss. 6, art. 2103
PID:20.500.12556/RUL-135400 Povezava se odpre v novem oknu
UDK:531.787
ISSN pri članku:1424-8220
DOI:10.3390/s22062103 Povezava se odpre v novem oknu
COBISS.SI-ID:100476931 Povezava se odpre v novem oknu
Datum objave v RUL:11.03.2022
Število ogledov:1120
Število prenosov:312
Metapodatki:XML DC-XML DC-RDF
:
SVETE, Andrej, HERNÁNDEZ CASTRO, Francisco Javier in KUTIN, Jože, 2022, Effect of the dynamic response of a side-wall pressure measurement system on determining the pressure step signal in a shock tube using a time-of-flight method. Sensors [na spletu]. 2022. Vol. 22, no. 6,  2103. [Dostopano 21 april 2025]. DOI 10.3390/s22062103. Pridobljeno s: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=slv&id=135400
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Sensors
Skrajšan naslov:Sensors
Založnik:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:09.03.2022

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:časovno spreminjajoči se tlak, primarna kalibracijska metoda, brezmembranske udarne cevi, metoda časa letenja, hitrost udarnega vala, piezoelektrični merilni sistemi za tlak, analiza negotovosti

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0223
Naslov:Prenos toplote in snovi

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:J2-3054
Naslov:Napredni sistem udarne cevi za visokofrekvenčno primarno dinamično tlačno umerjanje

Podobna dela

Podobna dela v RUL:
  1. E-novice CRP Gozdno-lesna veriga
  2. Potencialna raba bukovine in vrednotenje dodane vrednosti v izdelkih iz bukovine
  3. Učinek fizičnih dokazov na dodano vrednost v turizmu
  4. Predelava lesa v Bohinju
  5. Oblikovanje modela partnerstva dodane vrednosti v procesu obdavčevanja dohodkov iz čezmejnih poslov z vrednostnimi papirji
Podobna dela v drugih slovenskih zbirkah:
  1. Izhodišča za trajnostno oživitev gozdno-lesno predelovalne verige v Sloveniji
  2. Energetska samooskrba v krožnem gospodarstvu
  3. OCENA RAZVOJNEGA POTENCIALA GOZDNO-LESNE PREDELOVALNE VERIGE
  4. Razvoj modela za načrtovanje Centrov predelave lesa v sklopu gozdno-lesne verige
  5. SWOT analiza potenciala slovenske gozdno-lesno predelovalne verige

Nazaj