izpis_h1_title_alt

Design of vertical members in large-span steel structures - can relevance of seismic actions be exceeded on account of indirect fire actions?
ID Kolšek Češarek, Jerneja (Avtor), ID Češarek, Peter (Avtor)

URLURL - Izvorni URL, za dostop obiščite https://doi.org/10.1016/j.engstruct.2021.112907 Povezava se odpre v novem oknu
.pdfPDF - Predstavitvena datoteka, prenos (8,32 MB)
MD5: A088B9502DCB6F60F599F0203DC4DE9D

Izvleček
Effect of lateral actions evolving from restrained thermal expansions of horizontal structural elements (beams, slabs) on stability of vertical elements (columns, walls) of fire-engulfed buildings remains unaddressed some-times in engineering practice. Discussion with engineers has revealed that two reasons may contribute most to such design inconsistency. The first is premature assumptions that the effects of these actions can not be suffi-cient to exceed the effects of other lateral design actions, especially if for the same building considerable seismic influences are also expected. The second reason is the fact that, according to the present version of Eurocodes, these actions need not be addressed specifically if the design is carried out under standard fire curve. This curve, however, is still applied often in practice. For certain vertical members, such as the ones positioned somewhere within the middle of fire compartments, indirect lateral fire actions may indeed be negligible, e.g., due to partial or complete balancation of these actions in fire evolving simultaneously at two opposite sides. However, more pronounced effect might be observed for vertical members at the boundary between a fire-engulfed and a neighbouring cold-side compartment, especially in steel or RC buildings with larger horizontal spans prone to striking lateral thermal elongations. While such structures represent a fair share of existing building stock (they are common, e.g., in prefabricated industrial and commercial buildings), this problem deserves a special attention. In this paper two real one-storey large-span halls are analysed for confirmation of the above hy-pothesis. Each of them comprises two structurally connected units, i.e. one RC- and the other steel-framed, where fire is assumed to engulf the steel-framed unit. Stability of the cold-side RC columns at the boundary between both sectors is discussed and for the latter indirect fire actions from the connecting fire-engulfed steel members are found to be of a comparable or a greater size to effect of moderate-size seismic actions. The greatest effects of the observed fire actions are found at average steel temperatures below 400 C. This is a rather low temperature expected to be achieved (sooner or later) in most fire-affected steel elements with or without fire protection. At the same time, as in this paper also proven by results of exact visco-plastic structural computations, this is also a temperature at which no pronounced creep strains yet evolve in steel within time frames relevant for common structural fire analyses. In addition, the paper also shows that these conclusions would not change for other variations of the discussed two buildings where other possible kinematic boundary conditions were applied at the ends of the steel members or other possible thermal boundary conditions were assumed along their longitudinal surfaces. At most, the observed indirect fire effects would only increase further in these cases. Thus, at least for structures of a similar type (i.e. one-storey frame structures of horizontal spans of similar size and materials), the authors propose that the discussed lateral indirect fire actions are not dismissed from any design procedure regardless of the expected fire scenario as long as steel is allowed to heat to moderate temperatures (around 400 C). In the last part of the paper the authors also discuss possible change of these findings for multi-storey frame structures and/or frame structures of other spans. However, for these (and other possible) structural types, a more detailed further investigation is proposed.

Jezik:Angleški jezik
Ključne besede:steel, RC, Eurocodes, indirect fire actions
Vrsta gradiva:Znanstveno delo
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FGG - Fakulteta za gradbeništvo in geodezijo
Status publikacije:Objavljeno
Različica publikacije:Recenzirani rokopis
Poslano v recenzijo:22.09.2020
Datum sprejetja članka:24.07.2021
Datum objave:30.08.2021
Leto izida:2021
Št. strani:Str. 1-17
Številčenje:letn. 246, Št. 112907
PID:20.500.12556/RUL-131844 Povezava se odpre v novem oknu
UDK:624.04
ISSN pri članku:0141-0296
DOI:10.1016/j.engstruct.2021.112907 Povezava se odpre v novem oknu
COBISS.SI-ID:75140099 Povezava se odpre v novem oknu
Datum objave v RUL:04.10.2021
Število ogledov:801
Število prenosov:215
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Engineering structures
Skrajšan naslov:Eng. struct.
Založnik:Elsevier
ISSN:0141-0296
COBISS.SI-ID:7750666 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Začetek licenciranja:30.08.2021

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:jeklo, armiran beton, Evrokodi, posredni požarni vplivi

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0158
Naslov:Gradbene konstrukcije in gradbena fizika

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0260
Naslov:Mehanika konstrukcij

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah: