izpis_h1_title_alt

Design and clinical evaluation of a non-contact heart rate variability measuring device
ID Kranjec, Jure (Avtor), ID Beguš, Samo (Avtor), ID Geršak, Gregor (Avtor), ID Šinkovec, Matjaž (Avtor), ID Drnovšek, Janko (Avtor), ID Hudoklin, Domen (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (9,22 MB)
MD5: A684B494B455187D3FEACDDD1B614C34
URLURL - Izvorni URL, za dostop obiščite http://www.mdpi.com/1424-8220/17/11/2637 Povezava se odpre v novem oknu

Izvleček
The object of the proposed paper is to design and analyze the performance of a non-contact heart rate variability (HRV) measuring device based on ultrasound transducers. The rationale behind non-contact HRV measurement is the goal of obtaining a means of long term monitoring of a patient’s heart performance. Due to its complexity as a non-contact measuring device, influential physical quantities, error source and other perturbations were thoroughly investigated. For medical purposes it is of utmost importance to define the target uncertainty of a measuring method from the side of physicians, while it is the role of scientists to realistically evaluate all uncertainty contributions. Within this paper we present a novelty method of non-contact HRV measurement based on ultrasound transducers operating at two frequencies simultaneously. We report laboratory results and clinical evaluations are given for healthy subjects as well as patients with known heart conditions. Furthermore, laboratory tests were conducted on subjects during a relaxation period, and after 1 min physical activity.

Jezik:Angleški jezik
Ključne besede:heart rate measurement, heart rate variability, non-contact, ultrasound, clinical evaluation, target uncertainty
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2017
Št. strani:18 str.
Številčenje:Vol. 17, iss. 11, art. 2637
PID:20.500.12556/RUL-131005 Povezava se odpre v novem oknu
UDK:621.317:612.16
ISSN pri članku:1424-8220
DOI:10.3390/s17112637 Povezava se odpre v novem oknu
COBISS.SI-ID:11961684 Povezava se odpre v novem oknu
Datum objave v RUL:21.09.2021
Število ogledov:1511
Število prenosov:171
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Sensors
Skrajšan naslov:Sensors
Založnik:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:16.11.2017

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:merjenje srčnega utripa, spremenljivost srčnega utripa, brezkontaktno merjenje, ultrazvok, klinično testiranje, ciljna negotovost

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj