A rapid analysis of bisphenol A using MISPE coupled with HPLC-FLD in tissues of food-producing animals
ID
Cerkvenik, Vesna
(
Avtor
),
ID
Šturm, Sabina
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(1,69 MB)
MD5: 7935D569F836AE669D10837D584BFEFF
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S2215016121001448
Galerija slik
Izvleček
Bisphenol A (BPA) is a highly-produced organic compound of anthropogenic origin with a wide-range use and is ubiquitously present in both living organisms and the environment. A previously published analytical method for testing of the free (aglycone) BPA in foodstuffs was simplified and optimized for sheep muscle tissue, kidney and liver, by using only a single MISPE purification step allied with HPLC-FLD analysis. The recovery rates and RSD values over a concentration range of 1–10 μg/kg were in the range of 67–86% and 3–34%, respectively, while linearity in the matrix, represented by the r$^2$, was ≥0.999. LOD values were 0.5–1 μg/kg and LOQ values were 1 μg/kg. The analytical method used is a contribution to the field of veterinary toxicology and food testing and also proved to be applicable for other food-producing animal species, e.g. pigs, poultry and freshwater fish. The MISPE sorbent material for testing of BPA was reusable, with up to five re-use cycles without significant loss in performance characteristics. •The paper reports on a rapid determination of free (aglycone) BPA in tissues of food-producing animals by HPLC-FLD and presents a substantial improvement of analytical performance with regard to time- and cost-savings, as well as environmental protection. •MISPE is an advanced analytical technology, and the results proved that in a single and simplified SPE step it had good performance characteristics such as selectivity, recovery and precision, allied with low LOD and LOQ values. •It was proved that MISPE BPA cartridges could be used at least five times without significant loss of methodological recovery and precision.
Jezik:
Angleški jezik
Ključne besede:
bisphenol A
,
tissue analysis
,
solid phase extraction
,
molecularly imprinted polymers
,
liquid chromatography
,
bisphenol A-glycidyl methacrylate
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
VF - Veterinarska fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2021
Št. strani:
14 str.
Številčenje:
Vol. 8, art. 101351
PID:
20.500.12556/RUL-127091
UDK:
615.9
ISSN pri članku:
2215-0161
DOI:
10.1016/j.mex.2021.101351
COBISS.SI-ID:
62349827
Datum objave v RUL:
17.05.2021
Število ogledov:
1046
Število prenosov:
247
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
MethodsX
Založnik:
Elsevier
ISSN:
2215-0161
COBISS.SI-ID:
13645083
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Projekti
Financer:
ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:
P4-0092
Naslov:
Zdravje živali, okolje in varna hrana
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj